![]() |
![]() HP OpenVMS Systems Documentation |
![]() |
OpenVMS System Messages: Companion Guide for Help Message Users
SYSINIT-E-create process error on STARTUP, status = 'status'
SYSINIT-E-error allocating pool - error log buffers not copied, status
= 'status'
SYSINIT-E-error creating shadowed system disk, status = 'status'
SYSINIT-E-error loading message file, status = 'status'
SYSINIT-E-error loading RECOVERY_UNIT_SERVICES.EXE, status = 'status'
SYSINIT-E-error loading RMS.EXE, status = 'status'
SYSINIT-E-error mounting system device, status = 'status'
SYSINIT-E-error opening or mapping F11BXQP, status = 'status'
SYSINIT-E-error opening page file, status = 'status'
SYSINIT-E-error opening swap file, status = 'status'
SYSINIT-E-error opening system dump file, status = 'status'
SYSINIT-E-error reading system dump file error log buffers, status =
'status'
SYSINIT-E-error taking out lock on system disk, status = 'status'
SYSINIT-E-failed to create system logical names, status = 'status'
SYSINIT-E-page file or swap file control block initialization error,
status = 'status'
User Action: Correct the error using one of the following methods and reboot the system:
SYSINIT-E-recoverable error encountered when mounting system device,
status='status'
SYSINIT-E-unable to obtain lock for system ID resource, status =
'status'
SYSINIT-I- found a valid OpenVMS Cluster quorum disk
SYSINIT-I- no dump file - error log buffers not saved
SYSINIT-I- PAGEFILE.SYS not found - system initialization continuing...
SYSINIT-I- waiting to form or join an OpenVMS Cluster
SYSINIT-W- dump file write errors - error log buffers not saved
SYSINIT-W- invalid dump header version - error log buffers not saved
SYSLOG, unable to modify SYS$DEVICE/SYS$DISK logicals Facility: SHADOW, Volume Shadowing Software Explanation: Shadowing could not update system disk pointers and logical names to point to a virtual unit. User Action: Consult your system manager about the problem. The system manager can check error logs for device problems, change system parameter settings if necessary, or take other action to correct the problem. SYSPWDTMO, system password timeout Facility: LOGIN, Login Procedure Explanation: A user failed to correctly enter the system password within the allotted time period (as defined by the SYSGEN parameter LGI_PWD_TMO). This message is written to the system accounting and security audit records. The user does not receive a message when this error occurs. User Action: None. SYSTRMERR, SYSINIT-terminal IO error Facility: BUGCHECK, System Bugcheck Explanation: The OpenVMS software detected an irrecoverable, inconsistent condition. After all physical memory is written to a system dump file, the system automatically reboots if the BUGREBOOT system parameter is set to 1. User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a Compaq support representative and describe the conditions leading to the error. SYSVERCHK, system version mismatch - function aborted Facility: SYSGEN, System Generation Utility Explanation: An attempt to do a WRITE CURRENT operation failed because the SYSGEN.EXE version does not match the SYS.EXE version. User Action: Reenter the command, specifying the proper version of SYSGEN.EXE. SYSVERDIF, system version mismatch - reassemble and relink driver Facility: SYSGEN, System Generation Utility Explanation: A driver mismatch has been encountered. User Action: Reassemble and relink all drivers at each major release of the OpenVMS operating system. SZTOOBIG, record size or block size greater than 65534 Facility: MOUNT, Mount Utility Explanation: The record size specified by /RECORDSIZE or the block size specified by /BLOCKSIZE is greater than 65534. User Action: Correct the command and reenter it. TAPEALLODIFFF, The TAPE_ALLOCLASS parameter value for the processor Facility: STACONFIG, Standalone Configure Process Explanation: The value of the SYSGEN tape allocation class parameter differs between the local node and the specified remote node. User Action: Set the TAPE_ALLOCLASS parameter to the same nonzero value on both nodes. TAPEALLOZERF, This system and/or the processor on SCSI bus Facility: STACONFIG, Standalone Configure Process Explanation: The local node, remote node, or both nodes have the SYSGEN tape allocation class parameter set to zero. User Action: Set the TAPE_ALLOCLASS parameter to the same nonzero value for both nodes. TAPECLASS, fatal error detected by Tape Class driver (TUDRIVER) Facility: BUGCHECK, System Bugcheck Explanation: The OpenVMS software detected an irrecoverable, inconsistent condition. After all physical memory is written to a system dump file, the system automatically reboots if the BUGREBOOT system parameter is set to 1. User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a Compaq support representative and describe the conditions leading to the error. TAPEFULL, 'save-set-spec' is full Facility: BACKUP, Backup Utility Explanation: The specified volume contains file data that extends past the end-of-tape reflective strip, indicating that no space is available for more data. User Action: Retry the operation using another volume. TASKERROR, security server experienced a TASKING_ERROR exception Facility: SECSRV, Security Server Explanation: An error occurred in the security server. User Action: Contact a Compaq support representative. TIMORDSCB, Timeout attempting to read boot device SCB Facility: SHADOW, Volume Shadowing Software Explanation: Shadowing was not able to read the boot device storage control block (SCB) during boot time for the number of seconds specified in the SHADOW_SYS_TMO system parameter. User Action: Verify that the boot device is ready and that the volume is properly loaded on the device. TIMOUPDSCB, Timeout attempting to update system disk member SCBs Facility: SHADOW, Volume Shadowing Software Explanation: Shadowing was not able to update system disk member storage control blocks (SCBs) during boot time for the number of seconds specified in the SHADOW_SYS_TMO system parameter. User Action: Verify that the shadow set system disk devices are ready and that the volume is properly loaded on each device. TIPCUFLOW, NETACP - transmit count underflow Facility: BUGCHECK, System Bugcheck Explanation: The OpenVMS software detected an irrecoverable, inconsistent condition. After all physical memory is written to a system dump file, the system automatically reboots if the BUGREBOOT system parameter is set to 1. User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a Compaq support representative and describe the conditions leading to the error. TMSCPLDERR, TMSCP server must be loaded by setting SYSGEN parameter TMSCP_LOAD Facility: SYSGEN, System Generation Utility Explanation: An attempt was made to load the TMSCP server using the TMSCP command in SYSGEN. User Action: Always load the TMSCP server by setting the SYSGEN parameter TMSCP_LOAD to 1. This action loads the server, which services all locally connected MSCP type tape drives during SYSBOOT. TMSCPSERV, Fatal error detected by TMSCP server Facility: BUGCHECK, System Bugcheck Explanation: The TMSCP server encountered an irrecoverable error. User Action: Keep a copy of the crash dump and contact a Compaq support representative. TOOMANYARGS, 'command' expected 'number' arguments, but found 'number', at line 'line-number'. Facility: READ_CONFIG, File-Based Autoconfiguration Explanation: The command had too many arguments. The device description will not be added. User Action: Correct the condition and retry the operation. TOOMANYSUB, SPAWN failed, too many subprocesses. DIRECT mode used. Facility: STDRV, System Startup Driver Explanation: The startup database directed the startup driver to run too many spawned subprocesses. STDRV ran one or more of the processes in the main startup procedure using DIRECT mode. System startup should complete normally. User Action: Use SYSMAN's STARTUP commands to display and modify the startup database to spawn fewer subprocesses. TOO_MNY, too many of this device type Facility: SYSGEN, System Generation Utility Explanation: The SYSGEN command CONFIGURE specifies too many controllers for the given device type. User Action: Reenter the command with a valid number of controllers. TSRVALLOAD, the TMSCP server is already loaded Facility: SYSGEN, System Generation Utility Explanation: An attempt was made to load the TMSCP server using the TMSCP command in SYSGEN. The TMSCP server has already been loaded in the recommended way by setting the SYSGEN parameter TMSCP_LOAD to 1. This action loads the server, which services all locally connected MSCP-type tape drives during SYSBOOT. User Action: None. TWICE, device 'controller-name' - count changed from 'count' to 'count' Facility: SYSGEN, System Generation Utility Explanation: A controller name has been specified twice for the CONFIGURE command. User Action: Verify the value you intend to use. UBMAPEXCED, UNIBUS map register allocation exceeded Facility: BUGCHECK, System Bugcheck Explanation: The OpenVMS software detected an irrecoverable, inconsistent condition. After all physical memory is written to a system dump file, the system automatically reboots if the BUGREBOOT system parameter is set to 1. User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a Compaq support representative and describe the conditions leading to the error. UDAPORT, fatal error detected by UDA port driver (PUDRIVER) Facility: BUGCHECK, System Bugcheck Explanation: The OpenVMS software detected an irrecoverable, inconsistent condition. After all physical memory is written to a system dump file, the system automatically reboots if the BUGREBOOT system parameter is set to 1. User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a Compaq support representative and describe the conditions leading to the error. UNABLCREVA, unable to create virtual address space Facility: BUGCHECK, System Bugcheck Explanation: The OpenVMS software detected an irrecoverable, inconsistent condition. After all physical memory is written to a system dump file, the system automatically reboots if the BUGREBOOT system parameter is set to 1. User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a Compaq support representative and describe the conditions leading to the error. UNDEFLINK, undefined link Facility: LAT, LAT Facility Explanation: A link was specified that does not exist on the local node. User Action: Use the LATCP command SHOW LINK to see which links exist on the local node.
Unexpected Interrupt - CNF/PMC/PSR 'xxxxxxxx/xxxxxxxx/xxxxxxxx'
Unexpected Interrupt - NODESTS/CASR(H)/(L) 'xxxxxxxx/xxxxxxxx/xxxxxxxx'
UNEXPIOINT, unexpected I/O adapter interrupt Facility: BUGCHECK, System Bugcheck Explanation: The OpenVMS software detected an irrecoverable, inconsistent condition. After all physical memory is written to a system dump file, the system automatically reboots if the BUGREBOOT system parameter is set to 1. User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a Compaq support representative and describe the conditions leading to the error. UNEXPIRED, its expiration date is in the future Facility: BACKUP, Backup Utility Explanation: The Backup utility tried to mount a tape that cannot be initialized because it has an expiration date in the future. User Action: Mount another tape that can be initialized, or remove the /REWIND qualifier from the BACKUP command. UNKADAP, unknown adapter type encountered Facility: SYSGEN, System Generation Utility Explanation: An internal error occurred when SYSGEN tried to parse an adapter name. User Action: Check the command line for errors and reenter. UNKCPU, unknown CPU type encountered Facility: SYSGEN, System Generation Utility Explanation: An unknown CPU type was specified with the SYSGEN command SHOW/ADAPTER. User Action: Reenter the command, specifying a valid CPU type. UNKDEV, unknown device type Facility: MOUNT, Mount Utility Explanation: The device type is unknown or invalid. User Action: Correct the device name (or logical name if a logical name is specified) and reenter the command. UNKNOWNADAPTER, unknown adapter Type: 'text-string' at line 'line-number'. Facility: READ_CONFIG, File-Based Autoconfiguration Explanation: The ADAPTER type is unknown. The device description will not be added. User Action: Specify a valid adapter type and retry the operation. UNKNOWN_COMMAND, unknown command: 'keyword' at line 'line-number'. Facility: READ_CONFIG, File-Based Autoconfiguration Explanation: An unknown command was found and ignored. User Action: If the unrecognized text is insignificant, the process may continue without intervention. However, if the error was caused by a mistyped command, this condition can cause further errors. If possible, check your code and retry the operation. UNKNOWN_FLAG, unknown flag: 'text-string' at line 'line-number'. Facility: READ_CONFIG, File-Based Autoconfiguration Explanation: An unknown flag was specified. The device description will not be added. User Action: Specify a valid flag and retry the operation. UNKNPRQ, unknown Inter-processor Request Message Facility: BUGCHECK, System Bugcheck Explanation: The OpenVMS software detected an irrecoverable, inconsistent condition. After all physical memory is written to a system dump file, the system automatically reboots if the BUGREBOOT system parameter is set to 1. User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a Compaq support representative and describe the conditions leading to the error. UNKRSTRT, unknown restart code Facility: BUGCHECK, System Bugcheck Explanation: The OpenVMS software detected an irrecoverable, inconsistent condition. After all physical memory is written to a system dump file, the system automatically reboots if the BUGREBOOT system parameter is set to 1. User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a Compaq support representative and describe the conditions leading to the error. UNL_PEN, exec image unload is pending Facility: LOADER, Executive Image Loader Explanation: A call was made to LDR$UNLOAD_IMAGE to unload an executive image that is in use. The image is marked to be unloaded later. User Action: None. UNLOCKERR, failed to unlock volume Facility: RBLD, REBUILD Command (Mount Utility) Explanation: An error occurred while trying to unlock the volume. User Action: Take action based on the accompanying message.
Unrecognized SCA Packet - FLAGS/OPC/STATUS/PORT 'xx/xx/xx/xx'
UNRELVOL, volume is not part of volume set being mounted Facility: MOUNT, Mount Utility Explanation: A disk volume that is not part of a volume set was specified in a MOUNT command that specified other volumes. Only volumes belonging to the same volume set can be mounted using the same MOUNT command. User Action: Mount the specified volume using a separate command, or specify the /BIND qualifier in the MOUNT command. UNSUPRTCPU, unsupported CPU Facility: BUGCHECK, System Bugcheck Explanation: The OpenVMS software detected an irrecoverable, inconsistent condition. After all physical memory is written to a system dump file, the system automatically reboots if the BUGREBOOT system parameter is set to 1. User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a Compaq support representative and describe the conditions leading to the error. UNXINTEXC, unexpected interrupt or exception Facility: BUGCHECK, System Bugcheck Explanation: The OpenVMS software detected an irrecoverable, inconsistent condition. After all physical memory is written to a system dump file, the system automatically reboots if the BUGREBOOT system parameter is set to 1. User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a Compaq support representative and describe the conditions leading to the error. UNXSIGNAL, unexpected signal name in ACP Facility: BUGCHECK, System Bugcheck Explanation: The OpenVMS software detected an irrecoverable, inconsistent condition. After all physical memory is written to a system dump file, the system automatically reboots if the BUGREBOOT system parameter is set to 1. User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a Compaq support representative and describe the conditions leading to the error. USERAUTH, error accessing authorization record Facility: LOGIN, Login Procedure Explanation: The login processor cannot read the user record for this user. User Action: Try the operation again later. USEREXC, you are at maximum allowed processes for your user name Facility: LOGIN, Login Procedure Explanation: No more processes can be logged in under this user name. The EXQUOTA message simultaneously displays to the system manager. User Action: Wait until another process using this user name has logged out, and retry.
|