Your PPU system is shipped with the correct version of HP-UX and the PPU software bundle. If your system’s operating system is reinstalled with Ignite-UX, ensure that the correct version of HP-UX is used and the PPU software is reinstalled. See “Getting Started” for details. Because the PPU software can activate and deactivate cores, the following patches are required for PPU 8.x systems running HP-UX 11i v1:
For PPU Versions 8.x on |
![]() | |
![]() | ![]() |
![]() | |
![]() | NOTE: Updated firmware may be required by the NPar software, or by VPars software if you are using virtual partitions. Please check the product-specific documentation for additional requirements. |
![]() | |
![]() | ![]() |
![]() |
Your PPU system is shipped with the correct version of HP-UX and the PPU software bundle. If your system’s operating system is reinstalled with Ignite-UX, ensure that the correct version of HP-UX is used and the PPU software is reinstalled. See “Getting Started” for details.
You can easily upgrade the PPU software from versions 5.x, 6.x and 7.x to version 8.x. If you are running PPU version 4.x, the upgrade to version 8.x requires a utility meter. If you want to upgrade from PPU version 4.x to version 8.x, you can utilize an existing utility meter, or order a utility meter from HP. Contact your HP sales representative if you have questions about upgrading PPU software.
The following software is required for PPU versions 8.x on OpenVMS 8.3:
hp OpenVMS Industry Standard 64 Operating System V8.3, or later
PPU software bundle BA485AA (versions 8.x) — installed from the OpenVMS I64 8.3 OE DVD
WBEMCIM bundle (version A2.0-A051013F or higher) — optionally installed with OpenVMS 8.3
Network access to utility meter software version 7.3 (or higher)
The following software is required for PPU 7.1 on Windows Server 2003:
Windows
Server 2003, 64-bit
(either Enterprise or Datacenter edition)
WMI nPar Provider, 64-bit, version 2.0 or higher
WMI Mapper for Windows Server 2003 64-bit Edition, version 2.0 or higher
Baseboard Management Controller Driver (required by WMI nPar Provider), version 7.2.3790.3 or higher
Windows PPU installer cp006445.exe
Network access to a utility meter (version 7.3 or higher)
![]() | |
![]() | ![]() |
![]() | |
![]() | IMPORTANT: Windows PPU is only supported with the latest firmware, available on the Smart Setup media associated with HP Integrity Servers for Microsoft Windows Server 2003 64-bit version, Installer Media 4.5 or higher. |
![]() | |
![]() | ![]() |
![]() |
PPU is supported on Windows Server 2003 64-bit version, when hyperthreading is disabled. When hyperthreading is enabled and active, PPU does not report the correct usage information.
PPU is not supported on Windows Server 2003 64-bit version if it is running as an HPVM virtual machine (VM guest). PPU is supported on Windows Server 2003 64-bit version if it is running as an HPVM host. However, PPU does not report additional core usage information for the HPVM virtual machine (VM guest).
Your PPU system is shipped with the correct version of Windows Server 2003 and the PPU software. If your system’s operating system is reinstalled, ensure that the correct version of Windows, the PPU software, and other required components are used. See “Getting Started” for details.
No OS updates are known to be required at the time of publication of this document. The latest version of this document can be found online at: http://docs.hp.com. Future updates, including firmware, drivers and documentation can be found at http://www.hp.com/support/itaniumservers.