OpenVMS Debugger Manual
SET MODE
Enables or disables a debugger mode.
Format
SET MODE mode[,...]
Parameters
mode
Specifies a debugger mode to be enabled or disabled. Valid keywords are
as follows:
DYNAMIC
|
(Default) Enables dynamic mode. When dynamic mode is enabled, the
debugger sets modules and images automatically during program execution
so that you typically do not have to enter the SET MODULE or SET IMAGE
command. Specifically, whenever the debugger interrupts execution
(whenever the debugger prompt is displayed), the debugger automatically
sets the module and image that contain the routine in which execution
is currently suspended. If the module or image is already set, dynamic
mode has no effect on that module or image. The debugger issues an
informational message when it sets a module or image automatically.
|
NODYNAMIC
|
Disables dynamic mode. Because additional memory is allocated when a
module or image is set, you might want to disable dynamic mode if
performance becomes a problem (you can also free up memory by canceling
modules and images with the CANCEL MODULE and CANCEL IMAGE commands).
When dynamic mode is disabled, you must set modules and images
explicitly with the SET MODULE and SET IMAGE commands.
|
G_FLOAT
|
Specifies that the debugger interpret double-precision floating-point
constants entered in expressions as G_FLOAT (does not affect the
interpretation of variables declared in your program).
|
NOG_FLOAT
|
(Default) Specifies that the debugger interpret double-precision
floating-point constants entered in expressions as D_FLOAT (does not
affect the interpretation of variables declared in your program).
|
INTERRUPT
|
Useful when debugging a multiprocess program. Specifies that, when
program execution is suspended in any process, the debugger interrupts
execution in all other processes that were executing images and prompts
for input. See Chapter 15 for more information.
|
NOINTERRUPT
|
(Default) Useful when debugging a multiprocess program. Specifies that,
when program execution is suspended in any process, the debugger take
no action with regard to other processes.
|
KEYPAD
|
(Default) Enables keypad mode. Note that this parameter is not
available in the HP DECwindows Motif for OpenVMS user interface to the debugger. When
keypad mode is enabled, you can use the keys on the numeric keypad to
perform certain predefined functions. Several debugger commands,
especially useful in screen mode, are bound to the keypad keys. (Type
Help Keypad_Definitions_CI; also, use the SHOW KEY command to determine
the current key definitions.) You can also redefine the key functions
with the DEFINE/KEY command.
|
NOKEYPAD
|
Disables keypad mode. Note that this parameter is not available in the
HP DECwindows Motif for OpenVMS user interface to the debugger. When keypad mode is
disabled, the keys on the numeric keypad do not have predefined
functions, nor can you assign debugger functions to those keys with
DEFINE/KEY commands.
|
LINE
|
(Default) Specifies that the debugger display program locations in
terms of line numbers, if possible.
|
NOLINE
|
Specifies that the debugger display program locations as
routine-name + byte-offset rather than in terms of line
numbers.
|
SCREEN
|
Enables screen mode. Note that this parameter is not available in the
HP DECwindows Motif for OpenVMS user interface the debugger. When screen mode is
enabled, you can divide the terminal screen into rectangular regions,
so different data can be displayed in different regions. Screen mode
enables you to view more information more conveniently than the
default, line-oriented, noscreen mode. You can use the predefined
displays, or you can define your own.
|
NOSCREEN
|
(Default) Disables screen mode. Note that this parameter is not
available in the HP DECwindows Motif for OpenVMS user interface to the debugger.
|
SCROLL
|
(Default) Enables scroll mode. Note that this parameter is not
available in the HP DECwindows Motif for OpenVMS user interface to the debugger. When
scroll mode is enabled, a screen-mode output or DO display is updated
by scrolling the output line by line, as it is generated.
|
NOSCROLL
|
Note that this parameter is not available in the HP DECwindows Motif for OpenVMS user
interface to the debugger. Disables scroll mode. Note that this
parameter is not available in the HP DECwindows Motif for OpenVMS user interface to the
debugger. When scroll mode is disabled, a screen-mode output or DO
display is updated only once per command, instead of line by line as it
is generated. Disabling scroll mode reduces the amount of screen
updating that takes place and can be useful with slow terminals.
|
SYMBOLIC
|
(Default) Enables symbolic mode. When symbolic mode is enabled, the
debugger displays the locations denoted by address expressions
symbolically (if possible) and displays instruction operands
symbolically (if possible). EXAMINE/NOSYMBOLIC can be used to override
SET MODE SYMBOLIC for the duration of an EXAMINE command.
|
NOSYMBOLIC
|
Disables symbolic mode. When symbolic mode is disabled, the debugger
does not attempt to symbolize numeric addresses (it does not cause the
debugger to convert numbers to names). This is useful if you are
interested in identifying numeric addresses rather than their symbolic
names (if symbolic names exist for those addresses). When symbolic mode
is disabled, command processing might speed up somewhat, because the
debugger does not need to convert numbers to names. EXAMINE/SYMBOLIC
can be used to override SET MODE NOSYMBOLIC for the duration of an
EXAMINE command.
|
WAIT
|
(Default) Enables wait mode. In wait mode the debugger waits until all
processes under its control have stopped before prompting for a new
command. See Chapter 15 for more information.
|
NOWAIT
|
Disable wait mode. In nowait mode, the debugger immediately prompts for
new commands even if some or all processes are still running.
|
Description
For details about the SET MODE command, see the parameter descriptions.
The default values of these modes are the same for all languages.
Related commands:
EVALUATE
EXAMINE
DEFINE/KEY
DEPOSIT
DISPLAY
(SET,SHOW,CANCEL) IMAGE
(SET,SHOW,CANCEL) MODULE
SET PROMPT
(SET,SHOW,CANCEL) RADIX
(SET,SHOW) TYPE
(SHOW,CANCEL) MODE
SYMBOLIZE
Example
This command puts the debugger in screen mode.
SET MODULE
Loads the symbol records of a module in the current image into the
run-time symbol table (RST) of that image.
Notes
The current image is either the main image (by default) or the image
established as the current image by a previous SET IMAGE command.
By default, the debugger automatically loads symbols in a module as
needed. As such, this behavior makes the use of an explicit SET MODULE
command optional. For more information, see SET MODE DYNAMIC.
|
Format
SET MODULE [module-name[,...]]
Parameters
module-name
Specifies a module of the current image whose symbol records are loaded
into the RST. Do not use the asterisk (*) wildcard character. Instead,
use the /ALL qualifier. Do not specify a module name with /ALL or
/CALLS.
Qualifiers
/ALL
Specifies that the symbol records of all modules in the current image
be loaded into the RST.
/CALLS
Sets all the modules that currently have routines on the call stack. If
a module is already set, /CALLS has no effect on that module.
/RELATED (default)
/NORELATED
(Applies to Ada programs.) Controls whether the debugger loads into the
RST the symbol records of a module that is related to a specified
module through a with-clause or subunit relationship. Once loaded, you
can reference names declared in related modules within debugger
commands exactly as you reference them within the Ada source code.
Description
The SET MODULE command loads the symbol records of a module in the
current image into the run-time symbol table (RST) of that image.
Symbol records must be present in the RST if the debugger is to
recognize and properly interpret the symbols declared in your program.
The process by which the symbol records of a module are loaded into the
RST is called setting a module. This command also
supports user-provided mixed-case and lowercase module names on Alpha
and Integrity servers.
At debugger startup, the debugger sets the module containing the
transfer address (the main program). By default, dynamic mode is
enabled (SET MODE DYNAMIC). Therefore, the debugger sets modules (and
images) automatically as the program executes so that you can reference
symbols as you need them. Specifically, whenever execution is
suspended, the debugger sets the module and image containing the
routine in which execution is suspended. In the case of Ada programs,
as a module is set dynamically, its related modules are also set
automatically, by default, to make the appropriate symbols accessible
(visible).
Dynamic mode makes accessible most of the symbols you might need to
reference. If you need to reference a symbol in a module that is not
already set, proceed as follows:
- If the module is in the current image, use the SET MODULE command
to set the module where the symbol is defined or reference the symbol
with a fully-qualified path name. For example:
- If the module is in another image, use the SET IMAGE command to
make that image the current image, then use the SET MODULE command to
set the module where the symbol is defined.
If dynamic mode is disabled (SET MODE NODYNAMIC), only the module
containing the transfer address is set automatically. You must set any
other modules explicitly.
If you use the SET IMAGE command to establish a new current image, all
modules previously set remain set. However, only the symbols in the set
modules of the current image are accessible. Symbols in the set modules
of other images are temporarily inaccessible.
When dynamic mode is enabled, memory is allocated automatically to
accommodate the increasing size of the RST. If dynamic mode is
disabled, the debugger automatically allocates more memory as needed
when you set a module or an image.
If a parameter in a SET SCOPE command designates a program location in
a module that is not already set, the SET SCOPE command sets that
module.
For information specific to Ada programs, type Help Language_Support
Ada.
Related commands:
(SET,SHOW,CANCEL) IMAGE
SET MODE [NO]DYNAMIC
(SHOW) MODULE
Examples
This command sets module SUB1 (loads the symbol records of module SUB1
into the RST).
#2 |
DBG> SET IMAGE SHARE3
DBG> SET MODULE MATH
DBG> SET BREAK %LINE 31
|
In this example, the SET IMAGE command makes shareable image SHARE3 the
current image. The SET MODULE command sets module MATH in image SHARE3.
The SET BREAK command sets a breakpoint on line 31 of module MATH.
#3 |
DBG> SHOW MODULE/SHARE
module name symbols language size
FOO yes MACRO 432
MAIN no FORTRAN 280
...
SHARE$DEBUG no Image 0
SHARE$LIBRTL no Image 0
SHARE$MTHRTL no Image 0
SHARE$SHARE1 no Image 0
SHARE$SHARE2 no Image 0
total modules: 17. bytes allocated: 162280.
DBG> SET MODULE SHARE$SHARE2
DBG> SHOW SYMBOL * IN SHARE$SHARE2
|
In this example, the SHOW MODULE/SHARE command identifies all modules
in the current image and all shareable images (the names of the
shareable images are prefixed with SHARE$). The SET MODULE SHARE$SHARE2
command sets the shareable image module SHARE$SHARE2. The SHOW SYMBOL
command identifies any universal symbols defined in the shareable image
SHARE2. For more information, see the SHOW MODULE/SHARE command.
In this example, the debugger automatically loads the module
information when you specify the module name in the command. Debugger
ensures that the module information for module X is loaded, and then
locates the information for the routine named Y.
SET OUTPUT
Enables or disables a debugger output option.
Format
SET OUTPUT output-option[,...]
Parameters
output-option
Specifies an output option to be enabled or disabled. Valid keywords
are as follows:
LOG
|
Specifies that debugger input and output be recorded in a log file. If
you specify the log file by the SET LOG command, the debugger writes to
that file; otherwise, by default the debugger writes to
SYS$DISK[]:DEBUG.LOG.
|
NOLOG
|
(Default) Specifies that debugger input and output not be recorded in a
log file.
|
SCREEN_LOG
|
Specifies that, while in screen mode, the screen contents be recorded
in a log file as the screen is updated. To log the screen contents, you
must also specify SET OUTPUT LOG. See the description of the LOG option
regarding specifying the log file.
|
NOSCREEN_LOG
|
(Default) Specifies that the screen contents, while in screen mode, not
be recorded in a log file.
|
TERMINAL
|
Note
This parameter is not available in the
HP DECwindows Motif for OpenVMS user interface to the debugger.
|
(Default) Specifies that debugger output be displayed at the
terminal.
|
NOTERMINAL
|
Note
This parameter is not available in the
HP DECwindows Motif for OpenVMS user interface to the debugger.
|
Specifies that debugger output, except diagnostic messages, not be
displayed at the terminal.
|
VERIFY
|
Specifies that the debugger echo, on the current output device, each
input command string that it is executing from a command procedure or
DO clause. The current output device is by default SYS$OUTPUT (your
terminal) but can be redefined with the logical name DBG$OUTPUT.
|
NOVERIFY
|
(Default) Specifies that the debugger not display each input command
string that it is executing from a command procedure or DO clause.
|
Description
Debugger output options control the way in which debugger responses to
commands are displayed and recorded. For details about the SET OUTPUT
command, see the parameter descriptions.
Related commands:
@ (Execute Procedure)
(SET,SHOW) ATSIGN
(SET,SHOW) LOG
SET MODE SCREEN
SHOW OUTPUT
Example
|
DBG> SET OUTPUT VERIFY,LOG,NOTERMINAL
|
This command specifies that the debugger take the following actions:
- Output each command string that it is executing from a command
procedure or DO clause (VERIFY)
- Record debugger output and user input in a log file (LOG)
- Not display output at the terminal, except diagnostic messages
(NOTERMINAL)
SET PROCESS
Establishes the visible process or enables/disables dynamic process
setting.
Used only when debugging multiprocess programs (kept debugger only).
Format
SET PROCESS [process-spec[,...]]
Parameters
process-spec
Specifies a process currently under debugger control. Use any of the
following forms:
[%PROCESS_NAME]
process-name
|
The process name, if that name does not contain spaces or lowercase
characters. The process name can include the asterisk (*) wildcard
character.
|
[%PROCESS_NAME] "
process-name "
|
The process name, if that name contains spaces or lowercase characters.
You can also use apostrophes (') instead of quotation marks (").
|
%PROCESS_PID
process_id
|
The process identifier (PID, a hexadecimal number).
|
[%PROCESS_NUMBER]
process-number
(or %PROC
process-number)
|
The number assigned to a process when it comes under debugger control.
A new number is assigned sequentially, starting with 1, to each
process. If a process is terminated with the EXIT or QUIT command, the
number can be assigned again during the debugging session. Process
numbers appear in a SHOW PROCESS display. Processes are ordered in a
circular list so they can be indexed with the built-in symbols
%PREVIOUS_PROCESS and %NEXT_PROCESS.
|
process-set-name
|
A symbol defined with the DEFINE/PROCESS_SET command to represent a
group of processes.
|
%NEXT_PROCESS
|
The next process after the visible process in the debugger's circular
process list.
|
%PREVIOUS_PROCESS
|
The process previous to the visible process in the debugger's circular
process list.
|
%VISIBLE_PROCESS
|
The process whose stack, register set, and images are the current
context for looking up symbols, register values, routine calls,
breakpoints, and so on.
|
You can also use the asterisk (*) wildcard character to specify process
set all.
Do not specify a process with the /[NO]DYNAMIC qualifier.
Qualifiers
/DYNAMIC (default)
/NODYNAMIC
Controls whether dynamic process setting is enabled or disabled. When
dynamic process setting is enabled (/DYNAMIC), whenever the debugger
suspends execution and displays its prompt, the process in which
execution is suspended automatically becomes the visible process. When
dynamic process setting is disabled (/NODYNAMIC), the visible process
remains unchanged until you specify another process with the SET
PROCESS/VISIBLE command.
/VISIBLE
Makes the specified process the visible process. This switches your
debugging context to the specified process, so that symbol lookups and
the setting of breakpoints, and so on, are done in the context of that
process. When using /VISIBLE, you must specify one process.
Description
The SET PROCESS command establishes the visible process, defines the
current process set, or defines the visible process.
By default, commands are executed in the context of the visible process
(the process that is your current debugging context). Symbol lookups,
the setting of breakpoints, and so on, are done in the context of the
visible process.
Dynamic process setting is enabled by default and is controlled with
/[NO]DYNAMIC. When dynamic process setting is enabled, whenever the
debugger suspends program execution and displays its prompt, the
process in which execution is suspended becomes the visible process
automatically.
Related commands:
CALL
EXIT
GO
QUIT
SHOW PROCESS
STEP
Example
|
all> SET PROCESS TEST_Y
all> SHOW PROCESS
Number Name State Current PC
* 2 TEST_Y break PROG\%LINE 71
all>
|
The SET PROCESS TEST_Y command makes process TEST_Y the visible
process. The SHOW PROCESS command displays information about the
visible process by default.
|