![]() HP OpenVMS Systemsask the wizard |
![]() |
The Question is: Can OpenVMS 6.2 be run on an Blue box Alphaserver 800, if so which release do I need. The Answer is : AlphaServer 800 have an integrated UltraSCSI controller and thus require OpenVMS Alpha V7.1-1H1 or later, or can operate on OpenVMS Alpha V6.2-1H3 with the addition of an UltraSCSI ECO kit -- ALPSCSI*. Note that the AlphaServer 800 systems cannot boot off a standard OpenVMS Alpha V6.2-1H3 distribution, as this release does not include the necessary UltraSCSI ECO kit -- alternate mechanisms for standalone operations -- such as using a V7.1-1H1 or later OpenVMS Alpha kit or using another system sharing the same system disk -- for the initial bootstrap (prior to the application of the necessary kit), upgrades (to any releases prior to V7.1-1H1, which is the first release with UltraSCSI sypport) and for system disk restoration in the event of a failure must be made.
|