![]() HP OpenVMS Systemsask the wizard |
![]() |
The Question is: Dear all, I hope that you will answer this one ASAP, because this problem appeared immediately after 01-JAN-1999 and has affected all the executables that were working CORRECTLY since 31-dec-1998. All of the applications were developed on Microvax 3600/Vms 4.7, and modified after migration to Alpha system. The platform is AlphaServer 800/400Mhz running OpenVms v.7.1, and all the applications running were recompiled with DEC COBOL V.1.1-747 in FEB-1998 after the migration. We tried recompiling the source code of a specific program, but it doesn't work. When we SET TIME=XX-XXX-1998, EVERYTHING RUNS FINE, BUT ANY OTHER DATE OTHER THAN 1998 MAKES THE EXECUTABLE RUNNING IN A DEAD LOOP. We couldn't believe this and tried all the possible ways of solving the problem, including complete reinstallation of OpenVMS and Cobol, but we still can't find a remedy. The Answer is : You will want to use tools available to you -- such as the OpenVMS Source Code debugger -- to resolve this problem within the application. Without access to the complete application source code, any necessary data and data files, and information on the application requirements on the supporting environment, there is no way to answer the question. You will also want to check for the termination of one or more software licenses, either PAKs or application-specific mechanisms. The Wizard would not expect the reinstallation of the compiler nor the operating system nor the recompilation of the application sources would affect the incidence of the problem. This (initially) appears to be an application-specific coding problem. Questions requiring immediate answer should be directed to the Compaq Customer Support Center.
|