![]() HP OpenVMS Systemsask the wizard |
![]() |
The Question is: Dear Wizard, I was busy with a stand-alone backup to one of my disks when the power failed. I have a VAX 4000/96 and the disk giving the problem is a Seagate ST32171N (RZ28L-A) I tried the backup after the power failure again and the following message appear:- "FILE STRUCTURE ALLOCATION FAILURE". The backup command used = backup/verify/image/rewind mka500: dka300: I can boot using the other disk, but get the following error when trying to mount the problem disk:- "FATAL DRIVE ERROR" What is the problem with the disk? Will it be possible to fix the problem? Many Thanks Edwin The Answer is : Bootstrap OpenVMS off a recent distribution CD-ROM (root SYS1 on OpenVMS VAX V7.2) or off an alternate OpenVMS root, and try to INITIALIZE this disk, or use the BACKUP/INITIALIZE qualifer. (Depending on exactly what happened to the disk, you may end up needing to reformat or replace the disk -- the incidence of hardware failures resulting from power failures is not unknown.)
|