![]() HP OpenVMS Systemsask the wizard |
![]() |
The Question is: I have an Alpha 3000 model 500 with 2 external scsi drives which I use to boot 2 different versions of OpenVMS. One disk is loaded with 6.1 and the other is loaded with 7.1. I installed 6.1 first and the DecWindows login screen was presented normally at the end of the boot process. When I installed 7.1 onto the second drive, I had to upgrade the firmware to v7.0. After doing so, I successfully installed vms 7.1. The next time that I tried to boot the first disk loaded with 6.1, the Decwindows login screen was no longer displayed at the end of the boot process. The "X" cursor is displayed for a few moments and a gray bar appears at the bottom edge of the screen, flashes once and hangs. Do you know what can be done to resolve this situation? Thanks The Answer is : Please check for and apply the available ECO kit for the version of DECwindows in use -- DECwindows Motif V1.2-3, V1.2-4, or V1.2-5. The Customer Support Center will likely require relevent information from the SYS$MANAGER:DECW$*.LOG file -- problems with the DECwindows startup are generally logged in this file -- as well as information on the DECwindows version. A less desirable alternative would be a firmware downgrade. The OpenVMS Wizard would recommend an upgrade to OpenVMS Alpha V6.2, if that is possible -- support for OpenVMS V6.1 ended some time ago, and ECO kits (for new problems) are not typically available.
|