![]() HP OpenVMS Systemsask the wizard |
![]() |
The Question is: I have setup a TCP print queue on DEC 700-08 on port 16. Whenever a print job goes to the printer, it prints the job but all on one line. This printer is a HP Laserjet 5si. This printer works fine on PORT 1 as a LTA queue. Here's the command I used for setting up this queue and was wondering if there's something missing? $INITIALIZE/QUEUE/START/PROCESSOR=ucx$telnetsym/form=default/default=(nofeed,nob urst,notrailer,form=default)/retain=error/separate= (noflag,noburst,notrailer)/record_blocking/owner=[calg,*]/prot=(g:rsmd,w:rsmd)/o n="209.197.135.148:2016" calg$print: Here's the settings for the PORT 16; Character Size: 8 Input Speed: 9600 Flow Control: XON Output Speed: 9600 Parity: None Signal Control: Disabled Stop Bits: 1 Signal Select: CTS-DSR-RTS-DTR Access: Remote Local Switch: None Backwards Switch: None Name: PORT_16 Break: Disabled Session Limit: 4 Forwards Switch: None Type: Hard Default Protocol: Telnet Default Menu: None Preferred Service: None Authorized Groups: 0 (Current) Groups: 0 Enabled Characteristics: Autoprompt, Broadcast, Failover, Inactivity Logout, Input Flow Control, Lock, Loss Notification, Message Codes, Output Flow Control, Verification Any ideas??? The Answer is : Please upgrade to TCP/IP Services V4.2 with the current ECO. Please check that the version of the software loaded into the DECserver 700 is the most current available. Please check that the file(s) involved actually have a valid last line -- use the ANALYZE/RMS tool to check for a valid RMS file structure for the particular file(s). If the problem persists with the current versions, please contact the Compaq Customer Support Center directly for assistance.
|