![]() HP OpenVMS Systemsask the wizard |
![]() |
The Question is: I have a VAXstation 4000 Model 90 that displays the following message on the top of the screen: % DCL-I-SUPERSEDE, PREVIOUS VALVE OF SACDA$DISK HAS BEEN SUPERSEDE. also can I use the VAX withouT Mouse, and where can we Buy a mouse for vax 4000 model 90. The Answer is : As for your request for a replacement mouse, please contact Compaq Assisted Services, Compaq Services, your hardware support vendor, or a prefered third-party used-equipment vendor for pricing and availability. As for operating a DECwindows system without a mouse connected or with a failed mouse, please see the OpenVMS FAQ for the details of the available "dead rodent" mode. As for the SUPERSEDE message, the OpenVMS Wizard will assume that this message is displayed by a login or sylogin or other DCL command procedure, a procedure which uses the DEFINE or ASSIGN command, and particularly a procedure which overwrites an existing logical name. If you wish to suppress this, use the DEFINE/NOLOG qualifier. As for your current OpenVMS VAX version, the OpenVMS Wizard strongly recommends an upgrade to V6.2, V7.2, or V7.3 -- both user- and privileged-mode code are typically expected to continue to operate after an OpenVMS VAX upgrade from OpenVMS VAX V6.0 and later releases. From HELP/MESSAGE: SUPERSEDE, previous value of 'logical-name' has been superseded Facility: CLI, Command Language Interpreter (DCL) Explanation: The specified logical name was redefined. User Action: None.
|