HP OpenVMS Systemsask the wizard |
The Question is: I serch the jumper doc form RZ25-E scsi harddrive from my vaxstation 4000/60 The Answer is :
Please review the OpenVMS FAQ, and specifically the section
"Where can I get information on storage hardware?".
In the specific case of the RZ25 disk drive:
Drive front
_________________________________
| [J---7|
| PPPPP|
| 54321|
| |
| |
|J]P1 |
|-]P2 |
|-]P3 |
|-]P4 |
|-]P5 |
|-]P6 |
|-]P7 |
|6]P8 |
| |
| |
| P3[J|
| P2[-|
| P1[5|
+-------------------------------+
[_____________________][________]
SCSI connector DCvoltages
Jumper block J5 or J7 used to set the SCSI ID number
ID P1 P2 P3
0 OUT OUT OUT
1 OUT OUT IN
2 OUT IN OUT
3 OUT IN IN
4 IN OUT OUT
5 IN OUT IN
6 IN IN OUT
7 IN IN IN
Jumper block J6
----------------
P1 Selftest factory use only OUT
P2 Spin up on power applictation OUT
Wait for spin up command IN
P3 Not used OUT
P4 Write protect OUT
P5 Parity check enabled IN
P6 Reserved OUT
P7 Drive supplies power to SCSIbus IN
P8 Power to internal terminators IN
Jumper block J7
----------------
P4 Spindle sync option IN (Sync not used)
P5 For remote LED indicator
|