HP OpenVMS Systemsask the wizard |
The Question is: I serch the jumper doc form RZ25-E scsi harddrive from my vaxstation 4000/60 The Answer is : Please review the OpenVMS FAQ, and specifically the section "Where can I get information on storage hardware?". In the specific case of the RZ25 disk drive: Drive front _________________________________ | [J---7| | PPPPP| | 54321| | | | | |J]P1 | |-]P2 | |-]P3 | |-]P4 | |-]P5 | |-]P6 | |-]P7 | |6]P8 | | | | | | P3[J| | P2[-| | P1[5| +-------------------------------+ [_____________________][________] SCSI connector DCvoltages Jumper block J5 or J7 used to set the SCSI ID number ID P1 P2 P3 0 OUT OUT OUT 1 OUT OUT IN 2 OUT IN OUT 3 OUT IN IN 4 IN OUT OUT 5 IN OUT IN 6 IN IN OUT 7 IN IN IN Jumper block J6 ---------------- P1 Selftest factory use only OUT P2 Spin up on power applictation OUT Wait for spin up command IN P3 Not used OUT P4 Write protect OUT P5 Parity check enabled IN P6 Reserved OUT P7 Drive supplies power to SCSIbus IN P8 Power to internal terminators IN Jumper block J7 ---------------- P4 Spindle sync option IN (Sync not used) P5 For remote LED indicator
|