![]() HP OpenVMS Systemsask the wizard |
![]() |
The Question is: I have to remove the 2nd alpha 4100 Server and the Vax4000-300, so it leaves me just 1 Alpha4100 server which i connect (dssi) to the Sw800 first Hscp01 controller. 1) Question: As the Vax is removed from the 2nd controller do I need to terminate this 2nd controller port, or can i leave it open and still be dual redundant with only one controller connected with 1 alphaServer 4100. Kind Regards Ferry Eden Commerzbank (Nederland) N.V. Amsterdam. The Answer is : Yes, a DSSI bus does require proper termination. That said, there are a variety of ways that DSSI buses and DSSI controllers can be connected. Please contact your hardware support organization for assistance in reconfiguring your DSSI bus and your system hardware.
|