![]() HP OpenVMS Systemsask the wizard |
![]() |
The Question is: When performing zoning changes on a Brocade 12000 Core Fibre Switch. Disks on the VMS servers go into mount verification. Is there something we can do with the HBA to stop this ? The Answer is : Short answer: No. Longer answer: Mount verification occurs when an error that is deemed retryable and potentially fixable is returned on an I/O. When fibre channel switches are reconfigured, a temporary loss of connectivity between host and device happens. Any I/O attempted during that outage will cause mount verification to begin. That is the expected OpenVMS response to retryable I/O errors. As long as the SYSGEN parameter MVTIMEOUT (defaults to 3600 seconds) is not set to some very low value (less than a minute), the devices should exit mount verification when connectivity is restored. If MVTIMEOUT is set to expire before connectivity is restored, mount verification will time out, requiring a remount to make the device available.
|