![]() |
![]() HP OpenVMS Systemsask the wizard |
![]() |
The Question is: Dear Wizard, I own a DEC 150 AXP Alpha EV4 machine and I need information about the following DIAGNOSTIC codes shown by the SRM after a power-on self-test procedure: SCSI ?? 06 0050 From google's newsgroup I could find similar problem but with different machines and different codes and meanings. Would you please send a CHART with DIAGNOSTIC CODES meanings, with numbers and explanations ? I was misinterpreting the numbers 06 and 0050. They are not SCSI error messages, I guess. As far as I could see from others, they are most likely related to SELF TEST diagnostic codes which are specific for this particular machine. So, I suppose that 06 means TEST 06 failed and 0050 means TEST 50 failed, am I right ? I e-mailed you sometime ago but your answer was plainly about general hardware problem. I need a CHART with DIAGNOSTIC CODE and code explanations for this particular machine DEC Alpha XP 150 or DEC 2000 XP. thanks, Luiz Emediato The Answer is : Please contact your hardware services organization for diagnostics and hardware-level information -- the OpenVMS Wizard is familiar with OpenVMS, and does not particularly have nor particularly track hardware-services information. If you wish to perform your own hardware services -- if you perform self-maintenance of your local DIGITAL or Compaq Alpha hardware -- please see the Assisted Services program referenced in the OpenVMS Frequently Asked Questions (FAQ). As has been stated elsewhere here within the Ask The Wizard area, the SCSI controller within the DEC 2000 series -- the DECpc AXP 150 series was the Microsoft Windows NT variant of the DEC 2000 -- is exceedingly sensitive to the bus length, the signal integrity and the devices present on the SCSI. Any internal SCSI bus must be routed entirely within the box, for instance, and cannot be extended outside the enclosure. (3521), (4519) and other topics. The DEC 2000 SCSI is typically terminated at both ends of the bus, and you will want to follow normal practices for identifying and correcting SCSI configuration errors, such as using commands to determine if all devices are present and visible and operating at unique bus ids. ?? 06 SCSI 0050 would indicate an error related to a SCSI floppy at SCSI id 6 and -- though this error code is close to what was provided -- it does not exactly match the provided error code and thus may not be valid in this context. Again, the OpenVMS Wizard is not familiar with and cannot provide hardware-level services. Please consider self-maintenance services or enlisting the assistance of a hardware services organization.
|