;ษอออออออออออออออออออออออออออออออออออออออออออออออออออออออออออออออออป ;บ บ ;บ Olicom PC/MC Token-Ring Network Adapter บ ;บ Adapter Description File Version 1.10 บ ;บ Copyright 1989 by Olicom บ ;บ บ ;ศอออออออออออออออออออออออออออออออออออออออออออออออออออออออออออออออออผ AdapterID 00C83h AdapterName "Olicom PC/MC Token-Ring Network Adapter" NumBytes 3 FixedResources POS[3]=XX00XXXXb NamedItem Prompt "Primary or Alternate adapter" Choice "Primary I/O 0A20h - 0A2Fh" POS[1]=00XXXXXXb IO 0A20h - 0A2Fh Choice "Alternate I/O 1A20h - 1A2Fh" POS[1]=10XXXXXXb IO 1A20h - 1A2Fh Choice "Primary I/O 0A60h - 0A6Fh" POS[1]=01XXXXXXb IO 0A60h - 0A6Fh Choice "Alternate I/O 1A60h - 1A6Fh" POS[1]=11XXXXXXb IO 1A60h - 1A6Fh Help "PRIMARY OR ALTERNATE ADAPTER: Up to two Token-Ring Network adapters may be installed in this computer. An adapter may be either Primary, which is accessed at port addresses 0A20 through 0A2F, or Alternate, which is accessed at port addresses 1A20 through 1A2F. If one Token-Ring Network adapter is installed, it may be either Primary or Alternate. If two are installed, one must be defined as Primary and the other Alternate. The assignment for the Token-Ring Network adapter can be changed by selecting 'Change Configuration' and then using the F5=Previous and the F6=Next keys. If an assignment has an asterisk (*) by it, it is in conflict with another assignment and the port address must be changed. If a conflict continues to exist, you may have to change the assignments for other adapters or options that are in your computer to resolve the conflict." NamedItem Prompt "RPL EPROM Address location" Choice "EPROM Disabled" POS[1]=XX100XXXb Choice "D0000h - D7FFFh" POS[1]=XX010XXXb MEM 0D0000h - 0D7FFFh Choice "D8000h - DFFFFh" POS[1]=XX011XXXb MEM 0D8000h - 0DFFFFh Choice "C0000h - C7FFFh" POS[1]=XX000XXXb MEM 0C0000h - 0C7FFFh Choice "C8000h - CFFFFh" POS[1]=XX001XXXb MEM 0C8000h - 0CFFFFh Help "EPROM ADDRESS LOCATION: There are 4 possible 32K blocks of memory that can be assigned for accessing the EPROM area of the Token-Ring Network adapter. The preferred EPROM address for the adapter is: D0000 - D7FFF. The assignment for this EPROM address can be changed by selecting 'Change Configuration' and then using the F5=Previous and the F6=Next keys. The EPROM address selected must not be assigned for use by any other adapter or option. If an assignment has an asterisk (*) by it, it is in conflict with another assignment and the EPROM address must be changed. If a conflict continues to exist, you may have to change the assignments for other adapters or options that are in your computer to resolve the conflict." NamedItem Prompt "Interrupt Level" Choice "Interrupt 2" POS[0]=00XXXXXXb INT 2d Choice "Interrupt 3" POS[0]=01XXXXXXb INT 3d Choice "Interrupt 10" POS[0]=10XXXXXXb INT 10d Choice "Interrupt 11" POS[0]=11XXXXXXb INT 11d Help "INTERRUPT LEVEL: This Token-Ring Network adapter can operate on one of four interrupt levels: 2, 3, 10, or 11. The preferred interrupt level is 2, but the adapter can operate on any of the four levels if necessary. The assignment for this interrupt level can be changed by selecting 'Change Configuration' and then using the F5=Previous and the F6=Next keys." NamedItem Prompt "Bus Master Arbitration Level" Choice "Level 8" POS[3]=XXXX1000b ARB 8 Choice "Level 9" POS[3]=XXXX1001b ARB 9 Choice "Level 10" POS[3]=XXXX1010b ARB 10 Choice "Level 11" POS[3]=XXXX1011b ARB 11 Choice "Level 12" POS[3]=XXXX1100b ARB 12 Choice "Level 13" POS[3]=XXXX1101b ARB 13 Choice "Level 14" POS[3]=XXXX1110b ARB 14 Help "ARBITRATION LEVEL: The Bus Master Arbitration level need only be changed if it is in conflict with another adapter. Conflicting assignments are marked with an asterisk. Use the F5=Previous and the F6=Next keys to change arbitration level assignments if you are in the 'Change configuration' window."