AdapterID 0507Eh AdapterName "PIICEON SCSP-20 (2-serial) Adapter (Rev B)" NumBytes 2 NamedItem Prompt "SERIAL PORTS are configured to:" choice "COM-2,3 IRQ-3,3" pos[0] = 10101011b pos[1] = 00000000b io 2F8h-2FFh 3220h-3227h int 3 choice "COM-2,3 IRQ-3,NONE" pos[0] = 10001011b pos[1] = 00000000b io 2F8h-2FFh 3220h-3227h int 3 choice "COM-2,3 IRQ-NONE,3" pos[0] = 10100011b pos[1] = 00000000b io 2F8h-2FFh 3220h-3227h int 3 choice "COM-2,3 IRQ-NONE,NONE" pos[0] = 10000011b pos[1] = 00000000b io 2F8h-2FFh 3220h-3227h choice "COM-1,2 IRQ-4,3" pos[0] = 10110001b pos[1] = 00000000b io 3F8h-3FFh 2F8h-2FFh int 4 3 choice "COM-1,2 IRQ-4,NONE" pos[0] = 10010001b pos[1] = 00000000b io 3F8h-3FFh 2F8h-2FFh int 4 choice "COM-1,2 IRQ-NONE,3" pos[0] = 10100001b pos[1] = 00000000b io 3F8h-3FFh 2F8h-2FFh int 3 choice "COM-1,2 IRQ-NONE,NONE" pos[0] = 10000001b pos[1] = 00000000b io 3F8h-3FFh 2F8h-2FFh choice "COM-3,4 IRQ-3,3" pos[0] = 10101011b pos[1] = 00000010b io 3220h-3227h 3228h-322Fh int 3 choice "COM-3,4 IRQ-3,NONE" pos[0] = 10001011b pos[1] = 00000010b io 3220h-3227h 3228h-322Fh int 3 choice "COM-3,4 IRQ-NONE,3" pos[0] = 10100011b pos[1] = 00000010b io 3220h-3227h 3228h-322Fh int 3 choice "COM-3,4 IRQ-NONE,NONE" pos[0] = 10000011b pos[1] = 00000010b io 3220h-3227h 3228h-322Fh choice "COM-4,5 IRQ-3,3" pos[0] = 10101001b pos[1] = 00000010b io 3228h-322Fh 4220h-4227h int 3 choice "COM-4,5 IRQ-3,NONE" pos[0] = 10001001b pos[1] = 00000010b io 3228h-322Fh 4220h-4227h int 3 choice "COM-4,5 IRQ-NONE,3" pos[0] = 10100001b pos[1] = 00000010b io 3228h-322Fh 4220h-4227h int 3 choice "COM-4,5 IRQ-NONE,NONE" pos[0] = 10000001b pos[1] = 00000010b io 3228h-322Fh 4220h-4227h choice "COM-5,6 IRQ-3,3" pos[0] = 10101101b pos[1] = 00000010b io 4220h-4227h 4228h-422Fh int 3 choice "COM-5,6 IRQ-3,NONE" pos[0] = 10001101b pos[1] = 00000010b io 4220h-4227h 4228h-422Fh int 3 choice "COM-5,6 IRQ-NONE,3" pos[0] = 10100101b pos[1] = 00000010b io 4220h-4227h 4228h-422Fh int 3 choice "COM-5,6 IRQ-NONE,NONE" pos[0] = 10000101b pos[1] = 00000010b io 4220h-4227h 4228h-422Fh choice "COM-7,8 IRQ-3,3" pos[0] = 10101111b pos[1] = 00000010b io 5220h-5227h 5228h-522Fh int 3 choice "COM-7,8 IRQ-3,NONE" pos[0] = 10001111b pos[1] = 00000010b io 5220h-5227h 5228h-522Fh int 3 choice "COM-7,8 IRQ-NONE,3" pos[0] = 10100111b pos[1] = 00000010b io 5220h-5227h 5228h-522Fh int 3 choice "COM-7,8 IRQ-NONE,NONE" pos[0] = 10000111b pos[1] = 00000010b io 5220h-5227h 5228h-522Fh choice "Disable SCSP-20 Card" pos[0] = 10000110b pos[1] = 10000011b Help " COM implies Serial Port, and IRQ implies interrupt used. Example: COM-2,3 IRQ-3,3 .. If this choice is selected the SCSP-20 adapter card will be configured for COM Ports 2 & 3. Also, COM-2 will use interrupt 3 and COM-3 will use interrupt 3. To change selection use: F5 = previous choice F6 = next. "