AdapterId 07011h AdapterName"Tecmar MicroRAM AD Multifunction Board" NumBytes 6 FixedResources POS[0]=00000001b NamedItem Prompt "EMS Board Select" choice "Board 1" pos[2]=100XXXXXb io 0270h-0277h choice "Board 2" pos[2]=010XXXXXb io 0370h-0377h choice "Board 3" pos[2]=110XXXXXb io 0670h-0677h choice "Board 4" pos[2]=001XXXXXb io 0770h-0777h choice "Board 5" pos[2]=101XXXXXb io 0A70h-0A77h choice "Board 6" pos[2]=011XXXXXb io 0B70h-0B77h choice "Board 7" pos[2]=111XXXXXb io 0E70h-0E77h choice "Disable" pos[2]=000XXXXXb Help "The EMS page registers can be disabled or assigned to any of seven (7) I/O locations. Use the F5=Previous and the F6=Next keys to change this assignment in the 'Change configuration' window. Conflicting assignments are marked with an asterisk and must be changed to use the adapter." NamedItem Prompt "Serial Port 1 Interrupt Select" choice "Int 3 " pos[2]=XXXXXX00b int 3 choice "Int 4 " pos[2]=XXXXXX01b int 4 choice "Int 5 " pos[2]=XXXXXX10b int 5 choice "Int 9 " pos[2]=XXXXXX11b int 9 Help "This assignment need only be changed if it is in conflict with another assignment. Conflicting assignments are marked with an asterisk. Use the F5=Previous and the F6=Next keys to change arbitration level assignments if you are in the 'Change configuration' window." NamedItem Prompt "Serial Port 1 Address Select" choice "Disable" pos[3]=XXXXXX0Xb choice "COM1 " pos[3]=XXX00X1Xb io 03F8h-03FFh choice "COM2 " pos[3]=XXX01X1Xb io 02F8h-02FFh choice "COM3 " pos[3]=XXX10X1Xb io 03E8h-03EFh choice "COM4 " pos[3]=XXX11X1Xb io 02E8h-02EFh Help "This assignment need only be changed if it is in conflict with another assignment. Conflicting assignments are marked with an asterisk. Use the F5=Previous and the F6=Next keys to change arbitration level assignments if you are in the 'Change configuration' window." NamedItem Prompt "Serial Port 2 Interrupt Select" choice "Int 4 " pos[2]=XXXX01XXb int 4 choice "Int 3 " pos[2]=XXXX00XXb int 3 choice "Int 5 " pos[2]=XXXX10XXb int 5 choice "Int 9 " pos[2]=XXXX11XXb int 9 Help "This assignment need only be changed if it is in conflict with another assignment. Conflicting assignments are marked with an asterisk. Use the F5=Previous and the F6=Next keys to change arbitration level assignments if you are in the 'Change configuration' window." NamedItem Prompt "Serial Port 2 Address Select" choice "Disable" pos[3]=1XXXX0XXb choice "COM2 " pos[3]=100XX1XXb io 02F8h-02FFh choice "COM3 " pos[3]=101XX1XXb io 03E8h-03EFh choice "COM4 " pos[3]=110XX1XXb io 02E8h-02EFh Help "This assignment need only be changed if it is in conflict with another assignment. Conflicting assignments are marked with an asterisk. Use the F5=Previous and the F6=Next keys to change arbitration level assignments if you are in the 'Change configuration' window."