Symptom / Error | FRU / Action |
0010 0203 Not further explained |
1. System Board |
|
0011 0100 Serial connector error, possible system board failure |
1. Run Advanced Diagnostics |
0011 01XX / 0011 0200
0011 0600 / 0011 0800
0011 0900 |
1. System Board 2. Any Serial Device |
0011 02XX Card selected feedback error |
1. Run Advanced Diagnostics |
0011 03XX Port fails register check |
1. Run Advanced Diagnostics 2. System Board |
0011 06XX Serial option cannot be turned off |
1. Run Advanced Diagnostics 2. System Board |
0011 07XX |
1. Serial Device Cable 2. System Board |
0011 10XX Register test failed |
1. Run Advanced Diagnostics 2. System Board |
0011 16XX 16550 interrupt error |
1. Run Advanced Diagnostics |
0011 17XX Failed baud rate test |
1. Run Advanced Diagnostics |
0011 XXXX not listed above (See 'Power Supply Voltage Check' before replacing system board) |
1. System Board 2. Power Supply |
|
0012 01XX Second Serial Adapter. Check voltages |
1. System Board 2. Any Serial Device |
0012 02XX / 0012 06XX
0012 08XX / 0012 09XX
0012 XXXX |
1. Dual Async Adapter /A 2. System Board 3. Any Serial Device |
0012 07XX |
1. Communications Cable 2. Dual Async Adapter /A |
0012 9020 Disk cache error |
1. Cached Processor Option 2. System Board |
|
0013 01XX / 0013 02XX |
1. Game Adapter 2. Joystick |
|
0014 02XX Printer not ready |
Information only |
0014 03XX No paper error, or interrupt failure |
Information only |
0014 04XX System board timeout failure |
1. Run Advanced Diagnostics |
0014 05XX Parallel adapter error |
1. Run Advanced Diagnostics |
0014 06XX Presence test error |
1. Run Advanced Diagnostics |
0014 XXXX not listed above Check printer before replacing system board |
1. Printer 2. System Board |