Symptom / Error | FRU / Action |
0200 01XX to 0200 03XX |
1. Image Adapter /A, Image-I Adapter /A 2. Memory Module DRAM or VRAM |
0200 04XX |
1. Memory Module DRAM or VRAM 2. Image Adapter /A, Image-I Adapter /A |
0200 05XX to 0200 10XX |
1. Image Adapter /A, Image-I Adapter /A 2. Memory Module DRAM or VRAM |
0200 XXXX not listed above |
1. Image Adapter /A, Image-I Adapter /A 2. Memory Module DRAM or VRAM 3. System Board |
|
0201 01XX to 0201 03XX |
1. Printer/Scanner Option 2. Image Adapter /A 3. Memory Module DRAM or VRAM |
0201 04XX |
1. Memory Module DRAM or VRAM 2. Printer/Scanner Option 3. Image Adapter /A |
0201 05XX to 0201 10XX |
1. Printer/Scanner Option 2. Image Adapter /A 3. Memory Module DRAM or VRAM |
Image Adapter/A Memory Test failure indicated by graphic representation of adapter |
1. Replace memory module (shown in graphic) |
|
0206 XXXX |
1. SCSI-2 Adapter 2. Any SCSI Device 3. System Board |
|
0208 XXXX Verify that there are no duplicate SCSI ID settings on the same bus. |
1. Any SCSI Device |
|
for Error Code Format see: SCSI/Non-SCSI Error Code Format Codes |
for 0210XXXX 9xxx Error's see: SCSI Fixed Disk Diagn. Return Codes |
|
0210 XXXA (60MB)
0210 XXXB (80MB)
0210 XXXC (120MB)
0210 XXXD (160MB)
0210 XXXE (320MB)
0210 XXXF (400MB)
0210 XXXG (40MB)
0210 XXXH (1GB)
0210 XXXI (104MB)
0210 XXXJ (212MB)
0210 XXXM (2GB 8 bit 68-pin)
0210 XXXN (540MB)
0210 XXXO (1GB)
0210 XXXQ (540MB)
0210 XXXP (2GB 8 bit 50-pin)
0210 XXXU (Size unknown)
If it is an external device, check the external voltages. See 'SCSI Diagnostic Tests' and 'SCSI ID (Using to Help Isolate Failures' before replacing any FRUs |
1. SCSI Hard Disk Drive 2. SCSI Adapter or the SCSI controller built into the system board 3. SCSI Cable 4. SCSI ID Switch (On some models) |
0210 XXXX Internal bus, size unknown
0210 XXX1 External bus, size unknown |
1. SCSI Hard Disk Drive 2. SCSI Adapter or the SCSI controller built into the system board 3. SCSI Cable 4. SCSI ID Switch (on some models) |
|
0211 XXXX Check for any of the symptoms listed below. Or, if it is an external drive, and the power-on LED is off, check the external voltages. |
1. Tape Drive 2. SCSI Adapter or the SCSI controller built into the system board 3. SCSI Cable |
The amber LED remains on. |
1. Tape Drive 2. SCSI Cable (internal) 3. SCSI Adapter or the SCSI controller built into the system board |
The green 'in use' LED fails to come on. |
1. Tape Drive 2. SCSI Adapter or the SCSI controller built into the system board 3. SCSI Cable (internal) or SCSI Cable (external) |
The tape is automatically ejected from the drive. |
1. Tape Cassette 2. Drive |
SCSI ID on the rotary switch does not match the SCSI ID set in configuration. (Verify the drive switches inside the cover are set to zero) |
1. Rotary Switch Circuit Board 2. Circuit Board Cable 3. Tape Drive |
Tape sticks/breaks in the drive. Verify that the tapes used meet ANSI standard X3B5 |
1. Tape Cassette |
|
0212 XXXX |
1. SCSI Printer 2. Printer Cable |
0213 XXXX |
1. SCSI Processor |
0214 XXXX |
1. WORM Drive |
0215 XXXC 0215 XXXD 0215 XXXE 0215 XXXU If it is an external device, and the power-on LED is off, check external voltages. |
1. CD-ROM Drive I CD-ROM Drive II Enhanced CD-ROM II Any CD-ROM Drive 2. SCSI Cable 3. SCSI Adapter or the SCSI controller built into the system board |
0216 XXXX |
1. SCSI Scanner |
0217 XXXX If it is an external device, and the power-on LED is off, check external voltages. |
1. Rewriteable Optical Drive 2. SCSI Adapter or the SCSI controller built into the system board 3. SCSI Cable |
0218 XXXX Check for multi CD tray, or juke box. |
1. Changer |
0219 XXXX |
1. SCSI Communications Device |
|
0242 01Y0 / 0242 10Y0 Be sure the wrap plug is not missing. |
1. ISDN /2 Adapter 2. ISDN /2 Wrap Plug 3. ISDN /2 Communications Cable |
|
0243 XXXX |
1. XGA-2 Display Adapter |
|
0258 XXXX Video might have failed.
Ensure that you are using diagnostic files XGAANI.DGS and XGAPNI.DGS dated 03/06/93 or later before you replace any FRUs. Earlier files cause erroneous errors. |
1. XGA-2 Display Adapter 2. System Board |
|
0259 XXXX |
1. SVGA Adapter 2. System Board |
|
0260 XXXX |
1. System Board 2. Any SCSI Device |
|
0270 XXXX |
1. RAID Adapter Controller 2. System Board |
|
0271 XXXX |
1. RAID Hard Disk Drive 2. System Board |
|
0273 XXXX |
1. 1 Mbps MicroChannel Infrared 2. LAN Adapter |
|
0274 XXY0 Y = slot number XX = type of error
XX = 85 Configuration Compare failure
XX = 90 Adapter Test Card failure
XX = 91 Open Phase Test failure
XX = 92 Computer Problem
XX = 93 Transmit/Receive Test failure
XX = 99 General error |
1. LANStreamer MC 16 Adapter 2. System Board |
|
0275 01XX / 0275 03XX
0275 06XX / 0275 07XX |
1. ServerGuard Adapter 2. System Board |
0275 02XX / 0275 04XX
0275 10XX / 0275 11XX
0275 33XX / 0275 34XX
0275 36XX / 0275 37XX |
1. ServerGuard Adapter |
0275 09XX |
1. Remove redundant ServerGuard Adapters, run Auto Configuration program, then retest. |
0275 12XX |
1. WMSELF.DGS diagnostics file missing 2. WMSELF.DGS diagnostic file incorrect |
0275 35XX |
1. 3V Lithium Backup Battery 2. ServerGuard Adapter |
0275 54XX |
1. Internal Temperature out of range 2. ServerGuard Adapter |
0275 55XX / 0275 56XX |
1. ServerGuard Adapter 2. System Power Supply |
0275 57XX |
1. 7.2V NiCad Main Battery Pack 2. ServerGuard Adapter |
0275 58XX / 0275 59XX
0275 60XX / 0275 61XX |
1. PCMCIA Type II Modem 2. ServerGuard Adapter |
0275 62XX |
1. External Power Control Box not connected 2. External Power Control Box 3. ServerGuard Adapter |
0275 63XX / 0275 64XX |
1. External Power Control Box 2. ServerGuard Adapter |
0275 XXXX |
1. Update Diagnostic Software |
|
0278 01X0 / 0278 59X0 |
1. Personal Voice Dictation Adapter /A |
0278 61X0 / 0278 63X0 |
1. OS/2 Device Driver for Voice Dictation Adapter /A is missing. |
0278 64X0 |
1. Only one Voice Dictation PCMCIA Adapter is supported in a computer. |
0278 65X0 |
1. The PCMCIA enabler is unable to read the card information. |
0278 66X0 |
1. PCMCIA Card Socket Services not installed. |
0278 71X0 |
1. The VoiceType Dictation PCMCIA Card was not found. |
0278 80X0 / 0278 89X0 Speaker test failed. |
1. Check all Cables 2. Check external Speaker operation control |
0278 90X0 / 0278 99X0 Microphone test failed. |
1. Check all Cables 2. Check Microphone operating control |
|
0279 XXXX |
1. Fast/Wide Streaming RAID Adapter/A (FRU 06H3059)Pass through Card & Cable 2. System Board 3. Signal Pass Through Card (if installed) |
|
0281 XXY0 Y = slot number XX = type of error
XX = 85 Configuration Compare failure
XX = 90 Adapter Test Card failure
XX = 91 Open Phase Test failure
XX = 92 Computer Problem
XX = 93 Transmit/Receive Test failure
XX = 99 General error |
1. Dual LANStreamer MC32 Adapter |