Digital Clusters for Windows NT V1.1/V1.0
Supported Hardware List

This document is a compilation of the systems and options tested and supported by Digital Clusters for Windows NT V1.1 and V1.0, all Service Pack releases. Refer to the Digital Clusters for Windows NT V1.1 or V1.0 Configuration and Installation Guide for complete information on configuring your cluster.

Before using any of the hardware listed in the following pages, consult the documentation for your system to be sure your selected options are also supported on that system. Both the clusters software and your system must support the hardware in your clusters configurations.

If you are configuring Clusters with RAID 310, RAID 410 or RAID 450, ensure you have access to updated HSZ driver and RAID firmware. Contact terescik@ntsg.ako.dec.com for information.

AlphaServer Systems SCSI Bus Extenders
Prioris Server Systems RAID Controllers and Subsystems
Prioris Cluster-Ready Kits Disks
SCSI Adapters SCSI Cables
Storage Enclosuers Bus Terminators

Supported AlphaServer Systems

System I/O Bus Min ECU Min ARC Firmware
AlphaServer 4100
AlphaServer 4000
EISA/PCI V1.9 AlphaBIOS V5.28
AlphaServer 2100A 5/xxx
AlphaServer 2100 5/xxx
AlphaServer 2000 5/xxx
EISA/PCI V1.9 V4.51
AlphaServer 2100A 4/xxx
AlphaServer 2100 4/xxx
AlphaServer 2000 4/xxx
EISA/PCI V1.9 V4.50
AlphaServer 1000/1000A Model 5 EISA/PCI V1.9 AlphaBIOS V5.28
AlphaServer 1000/1000A EISA/PCI V1.9 V4.52
AlphaServer 800 EISA/PCI V1.10 AlphaBIOS V5.28
AlphaServer 400 ISA/PCI V1.9 V5.5

Supported Prioris Server Systems

System I/O Bus SCU System BIOS
Prioris MX Server EISA/PCI V1.02 V1.1
Prioris ZX 6000 Server EISA/PCI V1.03-01E V1.04
Prioris ZX 5000 Server EISA/PCI V3.30 V1.00.07.BGO
Prioris HX 6000 Server EISA/PCI V1.01 V1.0
Prioris HX 5000 Server EISA/PCI V1.01 V1.03
Prioris HX 590 Server EISA/PCI V1.08e V1.1
Prioris XL Server EISA/PCI V1.00
V1.02
V1.03
V1.05
V1.08
V1.1a
V1.00
V1.02
V1.04
V2.01
V2.04
V2.07

Cluster-Ready Kits for Prioris Servers

Digital Part Number Description
FR-BA356-NT Kit includes one BA356 storage enclosure, (2) 2944W adapters, DWZZB-VW signal converter, tri-link connector, SCSI cables, Y-cables, 2 network cards, terminators and QB-53V9A-SA Digital Clusters for NT software kit.
FR-BA356-N2 Expansion kit includes one BA356 storage enclosure and DWZZB-VW signal converters, Y cables, tri-link connectors. Pre-requisite is FR-BA356-N2.
FR-CK310-RF RAID 310 subsystem supporting up to 30GB capacity. Expansion kit available to support 7 additional drives. Drives must be purchased separately

Intel platform kit for RAID 310
Necessary RAID management software and firmware
(2) Adaptec 2944W SCSI adapters
Y cables, terminator, SCSI cables
(2) network interface cards and network cable for second network connection
QB-53V9A-SA Digital Clusters for NT software kit
FR-CK310-RU RAID 310 upgrade kit. Pre-requisite is FR-BA356-NT
FR-SWXRA-Z2 Expansion kit includes one BA346 storage enclosure and cabling for increasing storage capacity of RAID 310. Pre-requisite is FR-CK310-RF.

Supported SCSI Adapters

Each server system must have a supported SCSI adapter installed on the system expansion bus, in addition to any internal bus adapter shipped with the system. Digital strongly recommends that you disable or remove all internal termination and use Y cables or tri-link connectors to implement external termination.

Adapter Description Connector Driver Notes
Digital
KZPSA-BB
PCI-based Fast Wide Differential SCSI-2 controller 68 pin differential NT driver V1.41 required
deckzpsx.sys
FW A10 required
Supports AlphaServers only
Adaptec
AHA-2944W
PCI-based, fast wide differential SCSI-2 controller. 68 pin differential For Windows NT Server 3.51: aic78xx.sys V1.31LS

Supplied with Digital Clusters for WNT software.

For Windows NT Server 4.0:
aic78xx.sys V1.25b

Supplied with NT 4.0 Service Pack 2

  • Supports Prioris servers
  • Supported on all AlphaServer systems except the 4100.
  • Bus adapter requires a jumper when used in a multihost configuration. If you are using the adapter’s internal termination, install the jumper at the J5 jumper block.
  • BIOS versions 1.2x for the Adaptec AHA-2944W are not compatible with Digital Clusters for Windows NT because these versions of the BIOS provide no way of disabling bus reset.
  • BIOS 1.12 - 1.16 supported
  • Not compatible with the HSZ40RAID controller on AlphaServers.

Supported Storage Enclosures

The following disk storage expansion enclosures are supported.

Storage Enclosure Description Transmission Method Data Path Size Connector
BA346-KB Pedestal, 16 bit SCSI Single-ended Wide 68 pin
BA350-KB Pedestal, 8 bit SCSI Single-ended Narrow 50 pin high density
BA356-KC Expansion unit, 16 bit SCSI Single-ended Wide 68 pin

Note: Single-ended storage enclosures require a SCSI signal converter to connect to the supported adapters.

SCSI Bus Extenders and Signal Converters

Signal converters convert single-ended SCSI signals to differential SCSI signals. They are used to connect single-ended and differential bus segments to allow communication between devices with different transmission methods or to overcome cabling length restrictions on single-ended buses. Some signal converters also can be used to connect narrow single-ended devices to a wide differential bus. You can have a maximum of two signal converters installed between devices.

The following signal converters are supported.

Signal Converter Minimum Hardware Minimum Firmware Data Path Description
DWZZB-AA E01 A02 wide/wide Standalone product - Includes built-in universal power supply for general purpose SCSI bus length and signal conversion needs.
DWZZB-VW E01 A02 wide/wide StorageWorks building block. Installs in disk slot 0 in a BA356 or BA346 storage enclosure.
DWZZA-AA E02 n/a narrow/wide Includes DWZZA-MA (module for embedding in SCSI systems) and a power supply encased in small standalone unit. For use with BA350-KB.
DWZZA-VA F02 n/a narrow/wide StorageWorks building block. Installs in disk slot 0 in a BA350-KB storage enclosure.

Supported RAID Controllers and Subsystems

StorageWorks Platform Kits for Digital Clusters for Windows NT

The following platform kits make the addition of RAID storage to a Clusters for NT environment easier to configure and order. Refer to Sales Update article "StorageWorks Platform Kits for Digital’s Windows NT Clusters V1.0 software" in VTX IR or the LJSRV1::ALT1:[NT_CLSTR] directory for details. These kits assume that the customers owns or is planning to purchase StorageWorks RAID 310, RAID 410, RAID 450, or RAID configurations using HSZ40 or HSZ50 controllers.

Part Number Description Pre-requisites
SWDKT-DC Alpha/NT Clusters Platform Kit includes:
  • QB-53V9A-SA Clusters kit
  • One KZPSA-BB SCSI adapter
  • StorageWorks controller software
  • cables and documentation
AlphaServers
Network cards (4 recommended)
One of the following:
  • RAID 310 with SWDKT-DA NT/Alpha platform kit
  • RAID Array 410 with SWDKT-CA NT/Alpha platform kit
  • HSZ40s and one KZPSA-BB adapter
  • RAID Array 450 with QB-5JCAD-SA NT/Alpha platform kit
  • HSZ50s and one KZPSA-BB adapter
SWIKT-DC Intel/NT Clusters Platform Kit includes:
  • QB-53V9A-SA Clusters kit
  • One Adaptec 2944W SCSI adapter
  • StorageWorks controller software
  • cables and documentation
Prioris servers
Network cards (4 recommended)
One of the following:
  • RAID 310 with SWIKT-DA NT/Intel platform kit
  • RAID Array 410 with SWIKT-CA NT/Intel platform kit
  • HSZ40s and one Adaptec 2944W adapter
  • RAID Array 450 with QB-5JCAE-SA NT/Alpha platform kit
  • HSZ50s and one KZPSA-BB adapter
SWDKT-DD Windows NT Cluster Enabling Kit includes
  • StorageWorks controller software
  • cables and documentation for Alpha and Prioris servers
This upgrade kit includes everything the customer needs to upgrade from basic SCSI expansion JBOD storage to RAID.

StorageWorks HSZ40 RAID Controller Module

May be combined with various storage enclosures to create versatile RAID subsystems. Refer to the Digital Systems and Options Catalog, or StorageWorks business unit, for detailed configuration options and part numbers.

Controller Description Connector Firmware Notes
HSZ40-BA
HSZ40-Cx
RAID Array controller 68 pin differential V3.0Z-2 6-channel, various cache options
Requires V2.71 driver for HSZ

StorageWorks RAID 410 Sample Configuration and options

The following table represents one option for configuring a StorageWorks RAID Array 410 subsystem. Refer to the Digital Systems and Options Catalog, or StorageWorks business unit, for detailed configuration options and part numbers.

  Description Connector Firmware Notes
SWXRA-Y* RAID Array 410 subsystem 68 pin differential V3.0Z-2  
SWXD3-** Disk drive in Storage Works Building Block.     Quantity depends on the amount of storage required
SWIKT-CA WNT/Intel RAID Array 410 platform kit. Includes PCI/SCSI adapter.     For Intel systems with PCI
SWDKT-CA WNT/Alpha RAID Array 410 platform kit. Includes PCI/SCSI adapter.     For Alpha systems

StorageWorks HSZ50 RAID Controller Module

May be combined with various storage enclosures to create versatile RAID subsystems. Refer to the Digital Systems and Options Catalog, or StorageWorks business unit, for detailed configuration options and part numbers.

Controller Description Connector Firmware Notes
HSZ50-AF RAID Array controller 68 pin differential V5.0Z-1 6-channel, various cache options
Requires V3.2 driver for HSZ

StorageWorks RAID 450 Sample Configuration and options

The following table represents one option for configuring a StorageWorks RAID Array 450 subsystem. Refer to the Digital Systems and Options Catalog, or StorageWorks business unit, for detailed configuration options and part numbers.

  Description Connector Firmware Notes
DS-SWXRA-W0 RAID Array 450 subsystem 68 pin differential V5.0Z-1  
DS-SWXRA-W4 RAID Array 450 subsystem in rackmount enclosure 68 pin differential V5.0Z-1  
SWXD3-** Disk drive in Storage Works Building Block.     Quantity depends on the amount of storage required
QB-5JCAE-SA WNT/Intel RAID Array 450 platform kit. Includes PCI/SCSI adapter.     For Intel systems with PCI
QB-5JCAD-SA WNT/Alpha RAID Array 450 platform kit. Includes PCI/SCSI adapter.     For Alpha systems

StorageWorks RAID 310 Sample Configuration and options (1)

The following table represents one option for configuring a StorageWorks RAID Array 310 subsystem. Refer to the Digital Systems and Options Catalog, or StorageWorks business unit, for detailed configuration options and part numbers.

Digital Part Number Description Connector Firmware Notes
SWXRA-Z1 RAID Array 310 subsystem 68 pin differential V3.0 Dual power supplies
SWXRA-Z2 7-slot SBB expansion cab. 68 pin   Doubles storage capacity of 310
SWIKT-DA WNT/Intel RAID Array 310 platform kit. Includes PCI/SCSI adapter.     For Intel systems with PCI
SWDKT-DA WNT/Alpha RAID Array 310 platform kit. Includes PCI/SCSI adapter.     For Alpha systems

Supported Disks

Disk Device Description Data Path Minimum Firmware
RZ26L-VA 1.5GB disk in SBB Narrow 440C
RZ28B-VA 2.1GB disk in SBB Narrow 0006
RZ28C-VA 2.1GB disk in SBB Narrow 0004
RZ28D-VA 2.1GB disk in SBB Narrow 0008
RZ29B-VA 4.3GB disk in SBB Narrow 0014
RZ26L-VW 1.5GB wide disk in SBB Wide 442E
RZ28C-VW 2.1GB wide disk in SBB Wide 0004
RZ28D-VW 2.1GB wide disk in SBB Wide 0008
RZ29B-VW 4.3GB wide disk in SBB Wide 0014

Note: Only narrow drives are supported in the BA350 and RAID Array 410 enclosures

Supported SCSI Cables

The type of cables you need for your cluster depends on the hardware configuration. The following tables describes the supported cables and the context in which each cable would be used. Note that each supported cable comes in a variety of lengths. You must select cables such that the total length of the bus segment does not exceed its specified maximum.

Cable Connector Densities Use
50-Pin ("A")    
BN21V-0B
BN23G-nn or
BN21R-nn
One high, two low
One high, one low
This Y cable attaches to narrow devices and can be terminated if necessary.
These cables connect devices and cables with different connector densities.
68-Pin ("P")    
BN21W-0B
BN21K-nn or
N21L-nn
Three high
Two high
This Y cable attaches to wide devices and can be terminated if necessary.
These cables connect BN21W Y cables or wide devices

Note: nn denotes length in meters

Supported Bus Terminators and Connectors

You need terminators and connectors for the shared SCSI bus. This table describes the supported terminators and connectors and the context in which you would use them.

Type Description Density Pin Use
Terminator        
FR-PCXAR-WJ
H879-AA
(external vendor)
Single-ended, wide terminator
Wide differential terminator
High
High
68 pin
68 pin
Terminates wide cables
Terminates a tri-link connector or wide differential cable
Connector        
H885-AA
(external vendor)
Tri-link connector Three
high
Three
68 pin
Attaches to high-density, 68-pin cables or devices. Can be terminated if necessary. Electrically the same as a BN21W-0B.
BN21W-0B Wide Y cable   68 pin