Hi everyone,
I purchased this DEC 3000, MODEL 300X Workstation (DEC OSF/1 BASE 2USR DEC 3300), running ultrix.  
The machine used to work fine, but suddenly it is unable to boot up, because it fails in the initial 
power tests.  I have visually checked the outside connections, and my knowledge does not allow me to 
do much else.  The following is the exact output, after I switch it on:
DEC 3000 - M300X
DIGITAL EQUIPMENT CORPORATION
SYSTEM CONDUCTING POWER TESTS
--------------------------------------------------------
Devnam			Devstat
-------			---------
CPU			OK  KN16-CA -V3.3-S6EC-I15E-sV2.1 -DECchip 21064 P3.0-175
ASIC			OK
MEM			OK  48MB
NVR			OK
CXT			OK
SCC
**** System Machine Check Abort has occured ****
PC = 000DAF70
PS = 00000000.0016FA58
MCHK+000 = 00000000.000001E0
MCHK+008 = 000001A0.00000110
MCHK+010 = 00000001.00000092
MCHK+018 = 00000000.00000001
MCHK+020 = 000005F8.00000004
MCHK+028 = 00000000.0010E770
MCHK+030 = 00000000.00203004
MCHK+038 = 00000000.0010E770
MCHK+040 = 00000001.B0300000
MCHK+048 = 00000000.00104000
MCHK+050 = 00000000.00000000
    .    .    .    .   .
    .    .    .    .   .
    .    .    .    .   .
    .    .    .    .   .        	ETC ETC 
    .    .    .    .   .
    .    .    .    .   .
    .    .    .    .   .
MCHK+0A0 = 00000000.0011B518		FINALLY (LAST ROW)
    
After this point the system  is "hung", and the keyboard is stuck...There is not anything 
I can think of doing, except turning it off and then back on, but the same thing happens.
I would really appreciate your input,
George P.
Received on Sat Jan 27 1996 - 04:58:37 NZDT