Hi,
Recently we had a Digital service engineer install a TLZ7L-DA autoloader and 
an additional 4GB harddisk (rz29b) in our Digital AlphaServer 2000 4/233. 
This server currently has 1 2GB harddisk (rz28), 4 4GB harddisk (rz29b), 1 
internal cd-drom, 1 internal tape drive (TLZ07), 1 external tape drive 
(TLZ07) and one external autoloader (TLZ7L-DA). The kernel configuration 
file for the SCSI setup is as shown below :-
controller      scsi0      at psiop0    slot  0
device disk     rz0        at scsi0     drive     0
device disk     rz1        at scsi0     drive     8
device disk     rz2        at scsi0     drive     16
device disk     rz3        at scsi0     drive     24
device disk     rz6        at scsi0     drive     48
device tape     tz5        at scsi0     drive     40
controller      scsi1      at psiop1    slot  0
device tape     tz14       at scsi1     drive     112
device tape     tz13       at scsi1     drive     104
device disk     rz8        at scsi1     drive     64
I noticed that in the /var/adm/messages file the following error message is 
displayed during bootup :-
Oct 29 18:14:12 omc_pg4 vmunix: cam_logger: CAM_ERROR packet
Oct 29 18:14:12 omc_pg4 vmunix: cam_logger: bus 1 target 5 lun 0
Oct 29 18:14:12 omc_pg4 vmunix: ss_device_reset_done
Oct 29 18:14:12 omc_pg4 vmunix: Bus device reset has been performed
And when I try to run Advfs utilities I get the following error message in 
the console :-
Oct 29 18:16:13 omc_pg4 vmunix:  fd failure: No media in drive.
Another related problem is after the installation was done a few hours later 
the server suddenly froze for a few minutes and the /var/adm/messages file 
recorded the following error messages :-
Oct 28 20:44:15 omc_pg4 vmunix: Reached max abort count, scheduled bus reset
Oct 28 20:44:15 omc_pg4 vmunix: cam_logger: CAM_ERROR packet
Oct 28 20:44:15 omc_pg4 vmunix: cam_logger: bus 0
Oct 28 20:44:15 omc_pg4 vmunix: psiop_hardintr
Oct 28 20:44:15 omc_pg4 vmunix: Bus reset detected
Oct 28 20:44:15 omc_pg4 vmunix: cam_logger: CAM_ERROR packet
Oct 28 20:44:15 omc_pg4 vmunix: cam_logger: bus 0 target 5 lun 0
Oct 28 20:44:15 omc_pg4 vmunix: ctape_async
Oct 28 20:44:15 omc_pg4 vmunix: Bus reset notification
Oct 28 20:44:16 omc_pg4 vmunix: Hard Error Detected
Oct 28 20:44:16 omc_pg4 vmunix: DEC     TLZ07
My question here is how do you identify what is the problem here and what is 
the cause of the problem, and how do you fix this problem.
Any response will be much appreciated. Thank you.
Surash Natarajan
OTIS Engineering Center, Penang, Malaysia
surash_at_omc.otis.utc.com
Received on Tue Oct 29 1996 - 16:15:49 NZDT