Hi,
So far i received just one reply from
alan_at_nabeth.cxo.dec.com
He says that Termination, cable and connection problems usually show
up
as SCSI protocol errors and this doesn't appear to be one.
It may be worthwhile to check those things anyway, if the
disk is an external one.
In this case, the disk is not an external one. I'll try checking out
the hardware.
The original posting:
=========================================================
We have an installation which has 2 AS2100 4/275, working with DECsafe
1.2 and DU 3.2C (Rev 148).
Some days ago, in a random way, we are reading some weird messages
regarding the local bus, involving the O.S. disk. After this message
appears, we perceive a slow performance, which sometimes led us to
reboot the computers.
The message is as follows :
BTW, some weeks ago the system disk was changed due to a hard error.
********************************* ENTRY 17.
*********************************
----- EVENT INFORMATION -----
EVENT CLASS ERROR EVENT
OS EVENT TYPE 199. CAM SCSI
SEQUENCE NUMBER 7.
OPERATING SYSTEM DEC OSF/1
OCCURRED/LOGGED ON Thu Nov 28 08:35:08 1996
OCCURRED ON SYSTEM sapbd2
SYSTEM ID x00060009 CPU TYPE: DEC 2100
SYSTYPE x00000000
PROCESSOR COUNT 2.
PROCESSOR WHO LOGGED x00000000
----- UNIT INFORMATION -----
CLASS x0000 DISK
SUBSYSTEM x0000 DISK
BUS # x0000
x0000 LUN x0
TARGET x0
----- CAM STRING -----
ROUTINE NAME tmv2_continue_cbf
----- CAM STRING -----
corrupt host ping buffer
received
----- CAM STRING -----
ERROR TYPE Soft Error Detected
(recovered)
----- CAM STRING -----
DEVICE NAME DEC RZ28
********************************* ENTRY 18.
*********************************
================================================
Regards
JAN
- application/ms-tnef attachment: stored
Received on Tue Dec 03 1996 - 18:30:58 NZDT