HSZ40 Gurus: Software upgrade question

From: Guy Dallaire <dallaire_at_total.net>
Date: Mon, 27 Jan 1997 13:22:38 -0500 (EST)

Hello,

We're in the process of upgrading our current HSOF software (V2.7) to V-3.0x

Reading the upgrade procedures in the release notes, we saw that "DEC Does
not recommend the SAVE_CONFIGURATION parameters in a dual redundant
configuration"

That was NOT written in the V2.7 version of the software. We currently have
MULTIPLE DISKS containing the controller configuration. Is there a way to
remove that WITHOUT destroying the disks contents, before we do the upgrade
? We would also like to minimize the associated downtime.

                                        Thanks !

Guy Dallaire
dallaire_at_total.net

"God only knows if god exists"
Received on Mon Jan 27 1997 - 19:48:18 NZDT

This archive was generated by hypermail 2.4.0 : Wed Nov 08 2023 - 11:53:47 NZDT