I have a DECStation 433au with a 4 GB disk from DEC (RZ1CC-BA). I have added a
Quantum XP34550W as a second internal disk. I am now seeing the following
errors (as printed out by dia) on the second disk:
******************************** ENTRY 1 ********************************
Logging OS 2. Digital UNIX
System Architecture 2. Alpha
Event sequence number 2.
Timestamp of occurrence 05-JUN-1998 03:25:47
Host name soggy
System type register x0000001E Systype 30. (Miata)
Number of CPUs (mpnum) x00000001
CPU logging event (mperr) x00000000
Event validity 1. O/S claims event is valid
Event severity 5. Low Priority
Entry type 199. CAM SCSI Event Type
------- Unit Info -------
Bus Number 2.
Unit Number x0088 Target = 1.
LUN = 0.
------- CAM Data -------
Class x00 Disk
Subsystem x00 Disk
Number of Packets 10.
------ Packet Type ------ 258. Module Name String
Routine Name cdisk_rec_status
------ Packet Type ------ 256. Generic String
Recovery progress event, this is NOT an
error
------ Packet Type ------ 262. Info Error String
Error Type Information Message Detected (recovered)
------ Packet Type ------ 257. Device Name String
Device Name QUANTUM XP34550W LXY4
------ Packet Type ------ 256. Generic String
Active CCB at time of error
------ Packet Type ------ 256. Generic String
CCB request completed with an error
------ Packet Type ------ 1. SCSI I/O Request CCB(CCB_SCSIIO)
Packet Revision 76.
CCB Address xFFFFFC0007FA7580
CCB Length x00C0
XPT Function Code x01 Execute requested SCSI I/O
CAM Status x84 CCB Request Completed WITH Error
Autosense Data Valid for Target
Path ID 2.
Target ID 1.
Target LUN 0.
CAM Flags x000054C0 Data Direction (11: no data)
Disable the SIM Queue Frozen State
Place CCB at head of SIM Queue
Attempt Sync Data Xfer - SDTR
*pdrv_ptr xFFFFFC0007FA7228
*next_ccb x0000000000000000
*req_map x0000000000000000
void (*cam_cbfcnp)() xFFFFFC00004B0890
*data_ptr x0000000000000000
Data Transfer Length 0.
*sense_ptr xFFFFFC0007FA7250
Auotsense Byte Length 64.
CDB Length 6.
Scatter/Gather Entry Cnt 0.
SCSI Status x02 Check Condition
Autosense Residue Length x2E
Transfer Residue Length x00000000
(CDB) Command & Data Buf
15--<-12 11--<-08 07--<-04 03--<-00 :Byte Order
0000: 00000000 00000000 00000000 * ............*
Timeout Value x00000014
*msg_ptr x0000000000000000
Message Length 0.
Vendor Unique Flags x0000
Tag Queue Actions x00
------ Packet Type ------ 256. Generic String
Error, exception, or abnormal condition
------ Packet Type ------ 256. Generic String
NOT READY - Logical unit is NOT ready
------ Packet Type ------ 768. SCSI Sense Data
Packet Revision 0.
--- Sense Data For Device XP34550W (Quantum), 4GB 68 pin Wide -
7200RPM
Error Code x70 Current Error
Segment # x00
Information Byte 3 x00
Byte 2 x00
Byte 1 x00
Byte 0 x00
Sense Key x02 NOT READY
Additional Sense Length x0A
CMD Specific Info Byte 3 x00
Byte 2 x00
Byte 1 x00
Byte 0 x00
ASC & ASCQ x0402 Logical Unit is Not Ready, Initializing
Command Required.
FRU Code x00
Sense Key Specific Byte 0 x00
Byte 1 x00
Byte 2 x00
I am seeing the same thing on another 433au system that I have a Quantum
XP39100W and a Quantum Viking II 9.1 (I see it on both disks).
Any ideas?
--
Dr. Harry Edmon E-MAIL: harry_at_atmos.washington.edu
(206) 543-0547 FAX: (206) 543-0308
Dept of Atmospheric Sciences
University of Washington, Box 351640, Seattle, WA 98195-1640
Received on Fri Jun 05 1998 - 18:46:07 NZST