Hi managers,
My network administrator has added a new switch to accelerate our network
(100 Mb instead of 10Mb). So I've tried to change the ethernet controller
(DEC TULIP 10/100) configuration of my 4000 box at the SRM prompt as said
in the " System Drawer User's Guide " page 5-46 (" set ewa0_mode fastfd "
for 100BaseT full duplex instead of " twisted-pair " for 10BaseT). When I
reboot, I can see a message saying that 100BaseT mode has been selected,
but on the same line, I can read " full duplex : no link ". The led of the
switch for full duplex is not up, though the 100Mb leds on the switch and
ethernet controller of the 4000 are up.
Here's ifconfig -tu0 results :
# ifconfig tu0
tu0: flags=c63<UP,BROADCAST,NOTRAILERS,RUNNING,MULTICAST,SIMPLEX>
and here's uerf :
tu0: DEC TULIP (10/100) Ethernet
_Interface, hardware address:
_00-00-F8-30-24-B2
tu0: console mode: selecting
100BaseTX
_(UTP) port: full duplex: no link
What's wrong ?
Regards,
JD
___________________________________________________
Jacques DEMEULEMEESTER
Universite Charles de Gaulle Lille 3
Centre de Ressources Informatiques - Gestion
Rue du Barreau
BP 149
59653 Villeneuve d'Ascq cedex
Tel. : (33) 03 20 41 64 19
Fax : (33) 03 20 41 66 58 ou (33) 03 20 41 61 00
Mail : demeule_at_univ-lille3.fr
__________________________________________________
Received on Mon Jun 22 1998 - 09:22:34 NZST