SUMMARY: Alphaserver 1000A and disk problems

From: Harald Baumgartner <hmb_at_xray.mpe.mpg.de>
Date: Wed, 20 Jan 1999 16:47:52 +0100

problem is solved by DEC oh now COMPAQ by installing a new calbe for interal
bus.
The internal bus had a Wide SCSI-Disk and 2 narrow disks with a complicated
cable configuration.
Now one cable is installed for all internal disks. DEC/COMPAQ Component number:
17-04671-01, P.O.Number: 7ZC45W

second solution: a SCSI-cable tester, we tested all 3 external buses and in each
bus where more than 2 Terminations enabled. After we oppened the disk-boxes and
removed the jumpers for Terminaion enabled everything is fine, every reboot!

SCSI-cable tester (Digital-Component number):FE-ZZZOF-01 50$?

                        Thanks to DEC/COMPAQ-people, H. Baumgartner

-- 
Harald Baumgartner Max-Planck-Inst. fuer Extraterrestrische Physik
                   Postf. 1603, D-85740, Garching bei Muenchen, Germany
                   Phone :(Country Code 49) 89 3299-3346 (Fax: -3569)
                   e-mail: hmb_at_mpe.mpg.de, MPE::HMB
		   http://www.xray.mpe.mpg.de/~hmb/
Received on Wed Jan 20 1999 - 15:48:42 NZDT