SUMMARY : vmunix: Defering I/O (errno 5) for block ...

From: Bart Rousseau <roussea_at_uia.ua.ac.be>
Date: Mon, 22 Feb 1999 09:44:36 +0100

Hi,

I asked whether the following error message

vmunix: Defering I/O (errno 5) for block(0x76860, ox76860) on device
8,1026

that appeared in /var/adm/messages was a hardware error and
how I could check what disk was causing the error.

To find out which disk corresponds to device 8,1026 just do

ls -l /dev | grep 8 | grep 1026

Since these error messages point to a hardware error I will let the
owner of the machine contact Digital...

Thanks to
  Sean O'Connell
  alan_at_nabeth.cxo.dec.com
  V.S. Glukhov
  Paul Casteels
  Jim Belonis

Bart.
--
Bart Rousseau, Ph.D. student
University of Antwerp - Dep. of Chemistry
Structural Chemistry  - Quantum Chemistry
http://sch-www.uia.ac.be/struct/quantum/
Received on Mon Feb 22 1999 - 08:59:01 NZDT

This archive was generated by hypermail 2.4.0 : Wed Nov 08 2023 - 11:53:39 NZDT