out of ttys problem...

From: Saar Picker <saarp_at_uclink4.berkeley.edu>
Date: Wed, 24 Feb 1999 14:23:52 -0800

I just wanted a quick sanity check. We've got an AS2100 here running DU4.0d
PK3. Nptys was set to 255. However, up until recently, there were only 111 or
so of each tty and pty devices created. I've since created a total of 160 of
each. The system has NOT been rebooted since I've created the new devices, but
telnetd and others do not use the new devices and we're still limited to 111
simultaneous connections. Was there something I missed? Is there a way to fix
this without rebooting?

Thanks for any help.
-Saar

-- 
====================================================================
 Saar Picker                            saarp_at_socrates.berkeley.edu
 CCS/SDA - Administrative Unix                       (510) 643-8168
 UC Berkeley                                         261 Evans Hall
====================================================================
Received on Wed Feb 24 1999 - 22:26:34 NZDT

This archive was generated by hypermail 2.4.0 : Wed Nov 08 2023 - 11:53:39 NZDT