Hello Managers,
I'm going to have an electric maintenance this weekend and should properly
shutdown my AS4100 box connected to a RA7000 Raid array with dual redundant
HSZ70 controllers. All the disk storage is in the disk array including root
and usr.
I was reading in the list and in the HSZ70 documentation that is needed to
unmount all the filesystems in the raid array and then, from a terminal,
shutdown other_controller, shutdown this_controller, turnoff the power to the
subsyst., unplug the power cord and disable the ECBs.
My question is:
Is it the right procedure in this case that root and usr are in the RA700 and
the shutdown -h command is not possible? or do I disregard the unmount of the
filesystems? or ....
Any help will be appreciated
Thanks in advance,
Ada
ada_at_sentai.com
____________________________________________________________________
Get free email and a permanent address at
http://www.netaddress.com/?N=1
Received on Fri Aug 20 1999 - 16:31:32 NZST