SUMMARY: problem configuration RA7000

From: Juan Carlos Burbano <jburbano_at_uio.compuequip.com>
Date: Fri, 27 Aug 1999 08:13:06 -0500

Thanks to all who responded.
Especial
Alan
Dave Sill


I got a lot of tips. But the problem was the cable it wasn't correct
configuration.

> -----Original Message-----
> From: Juan Carlos Burbano [mailto:jburbano_at_compuequip.com] On
> Behalf Of Juan Carlos Burbano
> Sent: Jueves, 26 de Agosto de 1999 08:39 a.m.
> To: 'tru64 manager'
> Subject: problem configuration RA7000
>
> Hello
> I am trying to configuring RA7000 with a HSZ70 card to a ES40 the version
> of TRU64 is 4.0F and the version of the PCMCIA is 7.3 .
> I am connecting the HSZ70 to a terminal (Wyse) with the cable 17-04074-01
> (++A01) and a convertor 12-45238-03 the Wyse configured with 9600, 8bit,
> 1 stop and none pa.
> In moment that I pledge the equipment shows in screen the initialization
> of the controlling HSZ70 as follows
> Firmware Version: V73Z (00)
> Informational Report
> Instance Code:01010302
> Last Failure Code: 018000A0 ( No last Failure Parameters)
> HSZ70 >
> When it shows the Promt HSZ70 > not permits me to introduce any command
> I have treated to Configure direct serial conetion of the port of the
> serving to the port of maintenance of the controller , but we configure
> this for the moment add this line to the /etc/remote
> b9600:dv=/dev/tty00:br#9600:pa=none and to connect us use the command tip
> b9600, presents us a message of conected, but of I can not write nothing
> but.
> Try to executing the remote service of SSW but it does not find serving
> with the serial cable or with TCP/IP
> If have the configuration of the cable for conect of the PC to the HSZ70
>
> Beforehand thank you very much by your help.
>
Received on Fri Aug 27 1999 - 13:15:11 NZST

This archive was generated by hypermail 2.4.0 : Wed Nov 08 2023 - 11:53:39 NZDT