[SUMMARY:] Another problem with the firmware update.

From: Lindström Tony <tony.lindstrom_at_tekla.fi>
Date: Thu, 04 Nov 1999 11:46:10 +0200

> From: Olle Eriksson [mailto:olle_at_cb.uu.se]

> I did have this trouble once and this was because
> the reset/halt cable had incorrectly been connected
> to contact J4 instead of J5. These are located under
> the CD-ROM reader, in the right corner of the motherboard.
> J4 and J5 are identical, J4 are closest to the front, and
> it should not be in use.

Thank you Olle! This was the case!

(Below was the problem)

> > APU-E Manufacturing Header Incorrect
> > APU-E Manufacturing Header Incorrect
> >
> > *** Digital AlphaStation 500/333 -- Firmware Update ***
> >
> > Use HELP or ? for help
> >
> > Update
> > Verify
> > List
> > Show
> > DEbug
> > NDebug
> > ?
> > Apu-> update
> > Unknown (0x01)
> > APU-E ROM DEVICE JUMPER ON ?
> > Unknown (0x01)
> > APU-E ROM DEVICE JUMPER ON ?
> > Apu->