SUMMARY:panic

From: M selcukkaraca <selcuk.karaca_at_aski.gov.tr>
Date: Mon, 01 Jan 2001 16:14:29 -0800

Thanks to ;
Octave Orgeron
Tom Blinn
Fraser Macfarlane
Han Pilmeyer

My system : DU 4.0D
                    1x alpha 4000/4 MB CPU
                    256 MB RAM

Suggested solutions ;
1- look at the CPu fan and if not working replace it, Moreover check the
cable between the fan and motherborad
2- call the Compaq support;
3- look at SHOW POWER at the SRM console

I have checked the fans with
SHOW POWER
command ath the SRM console, but I got ;
Power Supply good
System Fans good
CPU Fans good
Temperature good

-----QUESTION -------
So if this is true then My fan should be working, Can I trust this output ??
Or should I open my Box and see the fan...


-----------------sent message------------------

hello admins,
today I have seen that our alpha 4000 system has been shutdown !
power button was in pressed state, but front panel indicator has no
electricity ( disks were on !)
I have played with plugs ( at the rear end) and it started to work.
Then I have seen it has been crashed ! I have got the following output with
dia

Question : Can I be sure that, this is the result of CPU fan problem ? Or is
there any other reason ?

Thank you for your help !


**** V3.3 ********************* ENTRY 3 ********************************


Logging OS 2. Digital UNIX
System Architecture 2. Alpha
Event sequence number 203.
Timestamp of occurrence 28-DEC-2000 02:58:15
Host name data

System type register x00000016 Alpha 4000/1200 Series
Number of CPUs (mpnum) x00000001
CPU logging event (mperr) x00000000

Event validity 1. O/S claims event is valid
Event severity 1. Severe Priority
Entry type 302. ASCII Panic Message Type
                                 -1. - (minor class)

SWI Minor class 9. ASCII Message
SWI Minor sub class 1. Panic

ASCII Message panic (cpu 0): System Uncorrectable
                                     Machine Check



**** V3.3 ********************* ENTRY 4 ********************************


Logging OS 2. Digital UNIX
System Architecture 2. Alpha
Event sequence number 202.
Timestamp of occurrence 28-DEC-2000 02:58:15
Host name data

System type register x00000016 Alpha 4000/1200 Series
Number of CPUs (mpnum) x00000001
CPU logging event (mperr) x00000000

Event validity 1. O/S claims event is valid
Event severity 1. Severe Priority
Entry type 100. Machine Check Error - (major class)
                                  1. - (minor class)


Software Flags x0000000300000000
                                     IOD 0 Register Subpkt Pres
                                     IOD 1 Register Subpkt Pres
Active CPUs x00000001
Hardware Rev x00000000
System Serial Number AY71232928
Module Serial Number
Module Type x0000
System Revision x00000000

Machine Check Reason x0208 Fatal Environmental Event Interrupt

Environmental Entry ---> System Environmental Register Follows
======================== =====================================

Sys Environmental Regs x0000C357 Function Reg<15:8>: x000000C3
                                     Failure Reg <7:0> : x00000057
                                     Power Supply 0 Present and Ok
                                     System Fans are OK
<<<HERE>>> PROBLEM with CPU Fan 0
<<<<<<<HERE>>>>>>>>>>>>
                                     Temperature is OK

PALcode Revision Palcode Rev: 1.21-26




selcuk.karaca_at_aski.gov.tr
Unix sys Admin
ASKI - ANKARA
Received on Mon Jan 01 2001 - 14:18:46 NZDT

This archive was generated by hypermail 2.4.0 : Wed Nov 08 2023 - 11:53:41 NZDT