Hello all,
we got the DPWS 433au up under Tru64 UNIX V5.1 with the
DE600 10/100 MBit Ethernet card and the on board Tulip in parallel.
Many thanks to Dr. Blinn and Veli Körkkö !!
- the DE600 is seen at the SRM console (show config) but without a
device name (e.g. eia0) and with no MAC address
the DE600 isn't supported anymore for these machines!
- for 433au and their last FW there are no SRM console variables to
deal with the card (mode, speed, ...)
- BUT going on and installing Tru64 UNIX V5.1 streight ahead configures
both cards and the DE600 has to be tweaked with
"ifconfig ... speed" if desired
Again many thanks and best regards
Uwe
--
Uwe Richter
Jena University, Faculty of Mathematics & Computer Science
Ernst-Abbe-Platz 1-4, Room#1219, D-07740 Jena, Germany
eMail: ur_at_inf.uni-jena.de Tel. : +49.3641.9.46044