Dear all,
I've just plugged in an RA310 from a DS20 with a good ol' KZPBA-CY to
a new DS20E which got shipped with an
itpsa0 at pci0 slot 9
IntraServer ROM Version V2.0 (c)1998
whatever the magic name for this one is... Well, to cut the long
story short the RA310 and this card are not on speaking terms:
cam_logger: CAM_ERROR packet
cam_logger: bus 2
itpsa SCSI HBA
160 MHZ clock did not lock
cam_logger: CAM_ERROR packet
cam_logger: bus 2 target 0 lun 0
ss_perform_timeout
timeout on disconnected request
Active CCB at time of error
cam_logger: CAM_ERROR packet
cam_logger: bus 2 target 0 lun 0
ss_perform_timeout
timeout on disconnected request
Active CCB at time of error
cam_logger: CAM_ERROR packet
cam_logger: bus 2 target 0 lun 0
ss_perform_timeout
Reached max abort count, scheduled bus reset
Active CCB at time of error
So, apart from "rip the old card out and flip it into the DS20E" does
anyone have any hints? It is rather obvious that the SCSI clocks are
rather unhappy with each other.
Ciao,
Arrigo
Received on Tue Feb 06 2001 - 00:26:46 NZDT