Richard Jackson pointed out an error in my original summary -- in fact, both
he & Werner Hahling told me this _before_ I incorrectly summarized. Sorry
for the bad info & wasted bandwidth.
In his words:
[I]t is important to wait one minute between steps 1 and 2 to give the
controller time to notice the change.
-----Original Message-----
I asked how to replace a failed drive from a RAID 1 pair on a 2100 attached
to an EISA 3-channel SWXCR controller. The extremely complicated answer:
1. Take out the old drive.
2. Put in the new drive.
Joseph
--
Joseph Thvedt
DBA/Unix administrator
jthvedt_at_larsondoors.com
Received on Thu Mar 15 2001 - 20:10:36 NZDT