SUMMARY: Alpha 3000-600

From: Itsa Secret <fishbait_at_fsmail.net>
Date: Tue, 22 May 2001 08:33:24 +0100 (GMT+01:00)

Thanks to Peter Stern, Ian Mortimer, Oisin McGuinness and Jörgen Pehrson.

Oisin pointed me towards DEC3000 300/400/500/600/700/800/900 AXPModels
System Programmer's Manual at:

http://wuarchive.wustl.edu/systems/unix/NetBSD/misc/dec-docs/alpha-sys-dec3000

Jörgen sent me an HTML document that gave the meanings of the LED's and the
recommended course of action for each state.

        Chris

Original question:
> I have an aging Alpha 3000 which has decided to turn up it's toes. I
> found it down on its heels at the console prompt. Tried to boot it but
> got
> INIT-S-CPU...
> INIT-S-RESET...
> then no further activity. I tried powering off and on but now get no
> console activity at all. I seem to remember having a document which
> detailed what the bank of eight LED's at the bank indicated of the
> stated of the hardware but I can't find it now. I wonder if anyone
> can point me to a source that will help me interpret them. Currently
> the machine shows LED's 4,5,6 & 7 as being on.




_______________________________________________________________________
FSmail - Get your free web-based email from Freeserve: www.fsmail.net
Received on Tue May 22 2001 - 07:33:28 NZST

This archive was generated by hypermail 2.4.0 : Wed Nov 08 2023 - 11:53:42 NZDT