Apologies for delving into the deep recesses of time, not to mention a pure
hardware question.
I've got an old HSZ40 controller whose cache battery has died. I've got a
replacement coming in tomorrow and, rather than have Compaq install it, was
doing to give it a go myself.
Has anyone replaced one of these before? My controllers are not
dual-redundant. I was just planning on doing a SHUTDOWN THIS_CONTROLLER,
then powering down the controller, pulling the cache board and swapping the
batteries, and then put it all back together. (All of this done only after
being properly grounded.)
Are there any pitfalls or advice to give?
thanks,
Chris
Received on Tue Jul 31 2001 - 19:03:12 NZST