Greetings,
Physically saw a dead drive on BA350 shelf. Ran
sys_check, and determined exactly which raid5 was
affected.
Quick Questions:
1. What commands does sys_check run (or i should run
from command line) to get this output below?
2. HOWTO replace drive (SWXCR) procedures somewhere?
-system needs to go down for this?
OR same as hsz controllers...just online?
3. Other command line tools for SWXCR i should be
aware about?
_Thanks in advance.
Richard
***** Logical Drive Information for xcr1 *****
Drive groups on this controller:
--------------------------------
Group 0 : <0,0><0,1><0,2><0,3>*0,4*<0,5><0,6>
Group 1 : <1,0><1,1><1,2><1,3><1,4><1,5><1,6>
Logical drives configured:
---------------------------
Logical Drive
Drive RAID Size Cache Group
Current
Number: Level: (in MB): Policy: Spanned:
Status:
---------------------------------------------------------
0 5 24546 WRITE THRU 0
DEGRADED
1 5 24546 WRITE THRU 1
OPTIMAL
SWXCR xcr1 physical drive parameters:
RAID Array 200 Controller Family Information Utility
V1.03
Copyright (c)1997,2000 by Compaq Computer Corporation,
all rights reserved.
***** Physical Device Information for xcr1 *****
Channel,
Wide/ Controller
Target: Vendor: Description: Firmware:
Narrow: Status:
-----------------------------------------------------------------------
<0,0> DEC RZ29B (C) DEC 0014 N
OPT
<0,1> DEC RZ29B (C) DEC 0014 N
OPT
<0,2> DEC RZ29B (C) DEC 0014 N
OPT
<0,3> DEC RZ29B (C) DEC 0014 N
OPT
*0,4* DEC RZ29B (C) DEC 0014 N
FLD
***** Status Check Summary for xcr1 *****
FAILED DISKS FOUND: 1
Failed Disks: *0,4*
=====
__________________________________________________
Do You Yahoo!?
Send instant messages & get email alerts with Yahoo! Messenger.
http://im.yahoo.com/
Received on Mon Aug 13 2001 - 18:30:11 NZST