SUMMARY: device naming problems during upgrade

From: Sauri Gudlavalleti <sauri_g_at_yahoo.com>
Date: Fri, 02 Nov 2001 11:02:12 -0800 (PST)

Dear Gurus:

Thanks very much to


        "McDowell, Paul" Paul.McDowell_at_celera.com
        "Udo de Boer" Udo.de.boer_at_ubero.nl
        "Brown, Phillip" Phillip.Brown_at_COMPAQ.com

for the prompt responses.

The solution was

# dsfmgr -vFV

I had earlier run dsfmgr -vF, and that did not help; the error I posted was
after that. the additional V option sorted it out.

Still there seem to be 3 out of the 24 errors, which relate to the floppy
drive, but since the machine is up, I will learn more about this and try to
solve it myself. Yesterday it was important to get the machine up.

Thanks a lot!

Sauri


-----Original Message-----
From: Sauri Gudlavalleti [mailto:sauri_g_at_yahoo.com]
Sent: Thursday, November 01, 2001 8:00 PM
To: tru64
Subject: device naming problems during upgrade



 
Hi,

 I tried to do an installupdate from Tru64 5.0 to 5.0A, but when the
installation procedure reboots the computer (DEC 600au), I get a long
list of device problems, ending with:
 
 Errors: Cluster 0 Local 0 Cluster/Local 24 Total: 24
 bcheckrc: Device Naming failed initial check.
     Correct errors and then continue or reboot.
 
 INIT: SINGLE-USER MODE
 #
 


 Does anyone know how to fix this problem?
 
 Thanks.
 
 

__________________________________________________
Do You Yahoo!?
Find a job, post your resume.
http://careers.yahoo.com
Received on Fri Nov 02 2001 - 19:02:56 NZDT