Hi guys,
Iam posting this message for the second time.
I have to build a 2 node cluster DS20E tru64 5.1A.
I am using personality module BA356 shelf which has 6
disks, i am able to see only four outof 6 disks.
This is because the three disks are old from digital
and have different serial numbers(2-5-2), but same
IEEE unique identifier,so the wwid created for these
three disks is same and so i see only 4 disks( three
new 1 old) and other two disks are shown under this 1
old disks as below.
sdp1:root:/> hwmgr sho scs -full -did 6
SCSI DEVICE DEVICE DRIVER
NUM DEVICE FIRST
HWID: DEVICEID HOSTNAME TYPE SUBTYPE OWNER
PATH FILE VALID PATH
-------------------------------------------------------------------------
106: 6 sdp1 disk none 0 3
dsk17
WWID:0c000008:0000-00ff-fe00-0000
BUS TARGET LUN PATH STATE
------------------------------
1 0 0 valid
1 1 0 valid
1 2 0 valid
The IEEE unique identifier was seen by show inquiry
pages on page 0*83 as below
Device Identification Page:
Page Code: 0x83
Page Length: 48
Code Set: 0x2 (identifier is
ASCII)
Identifier Type: 0x1
Identifier Length: 32
Vendor Unique Identifier: SEAGATE ST136475LC
3AM03AM5
Code Set: 0x1 (identifier is
binary)
Identifier Type: 0x2
Identifier Length: 8
IEEE Unique Identifier (EUI-64): 0xfffe000000
Is there any way i can chage the IEEE unique
identifier on this page( which is used to create wwid)
or create other wwid??
Thanks
Jay
=====
Jay Nash
E-mail:mgn321_at_yahoo.com