Summary: Problem loading LSM-OA license

From: McCracken, Denise <Denise.McCracken_at_misyshealthcare.com>
Date: Mon, 24 Mar 2003 13:52:29 -0700

        Thanks to Lecia Lynn for coming up with the answer to this almost as
fast as I could post it. ;)

        The answer it to change the number of units to 0.

-----Original Message-----
From: McCracken, Denise
Sent: Monday, March 24, 2003 1:46 PM
To: tru64-unix-managers_at_ornl.gov
Subject: Problem loading LSM-OA license



   OK, I have LSM support, but now I can't mirror the drives because the LSM
license won't load. The only time I've seen this error is with not enough
base licenses for the number of CPUs, and there is only one. Is 1050 not
enough units? This is what happens:

OSF1 newlab_at_stc:/etc # lmf reset
Not enough units to load LSM-OA DEC
Combine OSF-USR ALS-WM-95181-1151 with OSF-USR OSF-BASE-IMPLICIT-USER
OSF1 newlab_at_stc:/etc # sizer -p
1
OSF1 newlab_at_stc:/etc # lmf list
Product Status Users: Total
Active
 
LSM-OA enabled
DECEVENT terminated
OSF-DEV active unlimited
OSF-USR active unlimited
OSF-USR active, multiple unlimited
NET-APP-SUP-200 active unlimited
OSF-BASE active unlimited

OSF1 newlab_at_stc:/etc # lmf list full
           Product Name: LSM-OA
               Producer: DEC
                 Issuer: DEC
   Authorization Number: ALS-NQ-2000MAR29-1113
        Number of units: 1050
                Version:
   Product Release Date:
   Key Termination Date:
Availability Table Code: H
    Activity Table Code:
            Key Options: MOD_UNITS, ALPHA
          Product Token:
            Hardware-Id:
         License status: enabled
      Cancellation Date:
        Revision Number: 0
                Comment:

Any ideas?

thanks

-Denise
Received on Mon Mar 24 2003 - 20:45:49 NZST

This archive was generated by hypermail 2.4.0 : Wed Nov 08 2023 - 11:53:44 NZDT