HSG-80 Hiccup?

From: Ballowe, Charles <CBallowe_at_usg.com>
Date: Wed, 02 Apr 2003 14:01:03 -0600

Not entirely Tru64 but we had an incident Monday and are looking for
possible
explanations.

One of the disks in our HSG80 based SAN failed. The disk was part of a RAID
1+0 (stripped mirrorsets) unit. By the time I was alerted the controller had
replaced the disk with one from the spareset. My problem is that 2 Oracle
databases crashed when that happened and the system saw some I/O errors.
Everything
came up fine after a reboot, but I thought the technology in the SAN should
have
made such failures unnoticed to the users.

The HSG80 has Software V86F-1, the Tru64 system is running 5.1Apk3, and it
is oracle
v8.1.7.4.

Anybody seen something like that cause a database failure before?

Charles Ballowe /"\
Unix System Administrator \ / ASCII Ribbon Campaign
cballowe_at_usg.com X Against HTML Mail
x3896 / \
Received on Wed Apr 02 2003 - 20:00:56 NZST