SUMMARY: Using a vt320 to access the HSZ80 maintenance port

From: Karen Y Byrd <kybyrd_at_pobox.upenn.edu>
Date: Mon, 07 Jul 2003 11:23:52 -0400 (EDT)

 

I received this reply from Joseph Senulis:

 
 Hi Karen,
      We have a BC-16E-25 cable connecting our VT320 and HSZ80. I think that
 any (MMJ)terminal cable would work, but you want a ferrite collar at the
 HZZ80 end of the cable. Our cable has the collar built in, but you could
 easily add a collar to a cable that didn't have one. I am also not entirely
 sure if the collar is really needed but it is there to reduce noise on the
 cable.
 --Joe
 
 -----Original Message-----
 Subject: Using a vt320 to access the HSZ80 maintenance port
 
 
 I have a vt320 which just has 2 MMJ(modified modular
 jacks) serial connections on the rear.
 
 What cables and adapter(s) do I need attach this vt320
 to an HSZ80 controller maintenance port?
 
 TIA,

-- 
Karen Y. Byrd
Sys Admin/Oracle DBA
1322 Blockley Hall
Univ. of PA/ Sch. of Med.
Phila., PA 19104
v: 215-746-4968
f: 215-573-7645
Received on Mon Jul 07 2003 - 15:24:42 NZST