Admins,
My appreciation to all have responded and offered help.
This from /var/adm/messages indicates the card is there and the kernel 
is built with support for it.
Dec  3 17:04:13 pbsambk vmunix: isp0 at pci0 slot 14
Dec  3 17:04:13 pbsambk vmunix: isp0: QLOGIC ISP1040B/V2 - Differential 
Mode
Dec  3 17:04:13 pbsambk vmunix: isp0: Firmware revision 5.57 (loaded by 
console)
Dec  3 17:04:13 pbsambk vmunix: isp0: Fast RAM timing enabled.
Dec  3 17:04:13 pbsambk vmunix: scsi2 at isp0 slot 0
Additionally I had made one foolish blunder. I had failed to create the 
device files and they were not restored from the backup (?!). So I 
fixed that issue, reboot, still nothing... So...
 From the SRM prompt...
 >>> show dev
dqa0.0.13.0	DQA0
dqb0.1.13.0	DQb0
dqb1.1.13.0	DQb1
dva0.0.0.0	DVA0
ewa0.0.9.0	EWA0
ewa0.0.11.0	EWB0
pka0.7.0.14.0	PKA0
 >>> show PKA0
 >>>
This leads me to believe that I have an additional hardware issue.
Also Dr. Tom Blinn pointed out that I was not very verbose about the 
external storage device which I was not. This is an older storage 
shelf, circa 2000 with 6 18.2 Gb drives, raid 5.
Also the external storage is not shared between the production machine 
and the backup box.
I do not have a spare cable.
I am guessing the slot at the top of the pedestal is the array 
controller? Is there a trick to getting the drives out of this cabinet? 
Thanks very much all. I fear I will need a technician on site to look 
at this.
Mark
____________________________________________
Mark Hardman
SysAdmin/MIS
Bedford Times-Mail
812.277.7286
On Thursday, December 4, 2003, at 11:11 PM, mark_at_postman.tmnews.com 
wrote:
> Admins,
> We lost the main system disk in a DS10 that serves as a warm backup
> for one of production servers running a progress database. I have 
> replaced
> the drive, rsynced from my "live" server and now have the box "almost"
> back to full functionality with one very frustrating exception. This
> machine has an external storageworks drive array.
> From the console I do a show config and this tells me I have the Qlogic
> ISP10x0 card in the PCI slot. However I do not see the drives in the
> array. The external drives are where my apps and database lived. Have I
> missed something obvious. I have looked high and low for a driver and 
> come
> up empty handed. The HP/Compaq site has been of no help. This system is
> running 4.0g. I do not have any media with drivers and no docs. All I 
> have
> is the box. Any thoughts or guidance much appreciated. Right now we're
> running without a net other than standard tape and remote HD backup.
> Thanks in advance.
>
> Regards,
> Mark
> __________________________
> Mark Hardman, SysAdmin/MIS
> Bedford Times-Mail
> 812.277.7286
> mark_at_tmnews.com
>
>
Received on Fri Dec 05 2003 - 16:20:00 NZDT