We're recently migrated to Tru64 5.1B on our AlphaServers. I've set the
SCRIPT_TIMEOUT value on our caa application to a value that is sufficient
for all but the most extreme cases (i.e. it's not high enough if something
like a panic has occurred). If the caa start script timed out I assumed
it would automatically be retried since the target is ONLINE and the
state is OFFLINE. This isn't happening so is my assumption wrong or do
I need to set some other field?
Here is the info for the application's profile:
ACTIVE_PLACEMENT=0
AUTO_START=0
CHECK_INTERVAL=60
FAILOVER_DELAY=0
FAILURE_INTERVAL=0
FAILURE_THRESHOLD=0
HOSTING_MEMBERS=as00-00 as00-01
OPTIONAL_RESOURCES=
PLACEMENT=favored
REBALANCE=
REQUIRED_RESOURCES=
RESTART_ATTEMPTS=30
SCRIPT_TIMEOUT=300
Thanks in advance
Cathy M
cmykulyn_at_lucent.com
Received on Wed Apr 07 2004 - 15:51:24 NZST