SUMMARY: HSG80 Fan failure

From: Reiner Dassing <dassing_at_wettzell.ifag.de>
Date: Mon, 13 Sep 2004 16:49:27 +0200

Hi Managers!


My question was:

     After the command
        configuration reset
     the error
            Fan failure detected.
     still exists and the controller shuts down after some time.

I got a lot of answers very fast.
Many thanks to all who have answered especially to
Peter Reynolds, Greg Rudd and to Dr. Thomas Blinn.

They pointed me to a hardware problem by explaing the leds of EMU.

After refitting and cleaning all the electric contacts of all
fans the problem was solved.


-- 
Mit freundlichen Gruessen / With best regards
    Reiner Dassing
Received on Mon Sep 13 2004 - 14:51:51 NZST