Hello Tru64 Managers:
Thanks to all those who replied.
The problem was in the zoning of the SAN Switch. 
Once I found the problem, it was easy to fix.
Thanks a lot.
Praveen
The original posting:
----------------------------------------------------  
I am having a problem of all the MSA1000 volumes not
showing on the SRM Console of DS25 and DS15. Earlier,
we had the system in our facilities in California and
now the system is moved to a customer site in Manila,
Philippines. After booting the system up, I ran into
the problem of only one path to MSA1000 showing in the
SRM Console.
 
Following is our setup:
* 2 - MSA1000, and 2 - 2x16 San Switches. 
* 6 Alpha Servers (3 TruClusters). Each server has 2
FCA2384 cards, configured in NSPOF configuration. 
* 2 Windows Servers. 
* Zoning is active on the San Switches for
controllring which servers see which MSA1000. 
2 Zones, 1 tru64 and 1 windows. 
* Tru64 Zone contains all the Alpha Servers and one
MSA1000. 
* Windows Zone contains the two Windows Servers and
the other MSA1000.
Back in California, when I used to do a "show dev" on
SRM Console on a DS25, I used to see the following:
 
dgaXXX.XXXX.X.X.X          $X$DGAXXX         COMPAQ
MSA1000 VOLUME 4.xx
dgbXXX.XXXX.X.X.X          $X$DGBXXX         COMPAQ
MSA1000 VOLUME 4.xx
Dka0.0.0.1.2               DKA0              Compaq
BD036xxxxx HPB6 (36GB Disk Drive)
Dka100.1.0.1.2             DKA100            Compaq
BD036xxxxx HPB6  (36GB Disk Drive)
Dqa0.0.0.16.0              DQA0             
HL-DT-ST-RW/DVD GCC-4480 2.06 (DVD)
Dva0.0.0.1000.0            DVA0  
Ega0.0.0.5.2               EGA0             
xx-xx-xx-xx-xx-xx (10/100/1000 ethernet)
Eia0.0.0.8.0               EIA0             
xx-xx-xx-xx-xx-xx (10/100 ethernet)
Pga0.0.0.1.3               PGA0              WWN -
xxx…xxx (Fibre Channel bd)
Pgb0.0.0.2.3               PGB0              WWN -
xxx…xxx (Fibre channel bd)
Pka0.7.0.1.2               PKA0              SCSI Bus
ID 7 (Internal SCSI Bus)
Pkb0.7.0.101.2             PKB0              SCSI
Bus ID 7 (Internal SCSI Bus)
 
  
But, now, I see only dga and not dgb. In some alpha
servers, I see dgb and not dga.
Is there something I need to configure on the Alpha
Server or the MSA1000, so that I see both dga and dgb
devices in my SRM Console.
----------------------------------------------------
                
__________________________________ 
Do you Yahoo!? 
All your favorites on one personal page – Try My Yahoo!
http://my.yahoo.com 
Received on Sun Dec 12 2004 - 14:02:42 NZDT