Summary: FC disks

From: Nagy Ákos <akos.nagy_at_getronics.hu>
Date: Thu, 28 Apr 2005 18:40:54 +0200

Hi all,

Thanks to Nelson Kawumi:

> Run wwidmgr -quickset -udid indentifier
                        ^^^^^^^^^^^^^^^^^
I left this out. I assumed, which I shouldn't, that
without specifying "-udid <id>", the wwidmgr will
"collect" the first four disks with the smallest
value UDIDs. It doesn't.

Thank you again for the answers,
Regards,

Akos Nagy
Hungary

> Original question:
> >
> > Dear All,
> >
> > I had to replace a failed CPU main board of an
> > ES40 (not the PCI MB). The machine has a FC disk
> > storage system (HSG80) connected to it. After
> > the replacement, the disks (DGA1 etc.) can not be
> > seen. I've issued "wwidmgr -quickset" without
> > any success. What am I doing wrong? The FC cards
> > haven't been changed, replaced or modified at all,
> > and neither the HSGs.
> >
> > Many thanks for any help,
> > Regards,
> >
> > Akos Nagy
> > Hungary
> >
Received on Thu Apr 28 2005 - 16:42:52 NZST

This archive was generated by hypermail 2.4.0 : Wed Nov 08 2023 - 11:53:45 NZDT