Thanks to the many that responded.
Many responses suggested the fan may not be failed. Checking
connections, and board seating might fix the issue.
Another said that this is a known issue with ES40 models and might
require replacing the fan pci controller board. (54-30156-01)
Thanks
-----Original Message-----
From: Siebert, Aaron
Sent: Friday, May 06, 2005 3:01 PM
To: 'tru64-unix-managers_at_ornl.gov'
Subject: ES40 Fan2 failed
Managers,
We have an ES40 that the lcd panel displays "Fan2 failed"
Does anyone know which fan or replacement part this would require to
request from a vendor?
TIA
Regards,
Aaron Siebert
Nagrastar Customer Support Engineer
Aaron.Siebert_at_NagraStar.com
D - 3037065492 F - 3037065719