Hi Managers,
We have recently taken delivery of our first DS15. It is at a remote site.
I got local IT to connect a crossover serial cable to the com1 port and a
Windows server I can connect to using remote desktop; using PowerTerm on
the windows server.
All worked OK for a day, I could access the SRM console and RMC. But the
next day, half way through reading a man page, access over the com port
stopped.
I cannot even do the esc esc rmc sequence.
The DS15 has been powered down (power cable unplugged) and up again. I
talked local IT through setting console to graphics, running rmc and typing
clear port, to see if it corrected situation.
The com cable has been unplugged and re-inserted at both ends.
Does anyone have any ideas why it no longer responds over the serial cable?
I appreciate any and all ideas.
TIA
Shaun
Received on Tue Nov 22 2005 - 17:11:25 NZDT